EVB9311 SMSC, EVB9311 Datasheet - Page 94

EVALUATION BOARD LAN9311-NU

EVB9311

Manufacturer Part Number
EVB9311
Description
EVALUATION BOARD LAN9311-NU
Manufacturer
SMSC
Series
0133r
Datasheet

Specifications of EVB9311

Main Purpose
Interface, Ethernet
Embedded
No
Utilized Ic / Part
LAN9311
Primary Attributes
2 Ports, 100BASE-TX/10BASE-T, Managed
Secondary Attributes
2 PHYs with HP Auto-MDIX, Auto- Flow Control, 32-bit CRC, MDI/MDI-X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1076
Revision 1.7 (06-29-10)
7.2.8
7.2.8.1
7.2.9
Auto-Negotiation LP Acknowledge
Link Down (Link Status Negated)
Auto-Negotiation Page Received
For a transmission, the switch fabric MAC drives the transmit data onto the internal MII TXD bus and
asserts TXEN to indicate valid data. The data is in the form of 4-bit wide data at a rate of 25MHz for
100BASE-TX, or 2.5MHz for 10BASE-T.
For reception, the 4-bit data nibbles are sent to the MII MAC Interface block. These data nibbles are
clocked to the controller at a rate of 25MHz for 100BASE-TX, or 2.5MHz for 10BASE-T. RXCLK is the
output clock for the internal MII bus. It is recovered from the received data to clock the RXD bus. If
there is no received signal, it is derived from the system reference clock.
PHY Management Control
The PHY Management Control block is responsible for the management functions of the PHY,
including register access and interrupt generation. A Serial Management Interface (SMI) is used to
support registers 0 through 6 as required by the IEEE 802.3 (Clause 22), as well as the vendor specific
registers allowed by the specification. The SMI interface consists of the MII Management Data (MDIO)
signal and the MII Management Clock (MDC) signal. These signals interface to the Host MAC and
allow access to all PHY registers. Refer to
for a list of all supported registers and register descriptions. Non-supported registers will be read as
FFFFh.
PHY Interrupts
The PHY contains the ability to generate various interrupt events as described in
the
the interrupt, and clears the interrupt signal. The
(PHY_INTERRUPT_MASK_x)
block aggregates the enabled interrupts status into an internal signal which is sent to the System
Interrupt Controller and is reflected via the
the Port 1 PHY, and bit 27 (PHY_INT2) for the Port 2 PHY. For more information on the
LAN9311/LAN9311i interrupts, refer to
PHY Power-Down Modes
There are two power-down modes for the PHY:
Note: For more information on the various power management features of the LAN9311/LAN9311i,
Auto-Negotiation Complete
Parallel Detection Fault
INTERRUPT SOURCE
Remote Fault Detected
ENERGYON Activated
PHY General Power-Down
PHY Energy Detect Power-Down
Port x PHY Interrupt Source Flags Register (PHY_INTERRUPT_SOURCE_x)
refer to
Section 4.3, "Power Management," on page
Table 7.3 PHY Interrupt Sources
enables or disables each PHY interrupt. The PHY Management Control
DATASHEET
Chapter 5, "System Interrupts," on page
94
Interrupt Status Register (INT_STS)
Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface
Section 14.4.2, "Port 1 & 2 PHY Registers," on page 287
PHY_INTERRUPT_SOURCE_x REGISTER BIT #
PHY_INTERRUPT_MASK_x &
Port x PHY Interrupt Mask Register
46.
7
6
5
4
3
2
1
SMSC LAN9311/LAN9311i
49.
bit 26 (PHY_INT1) for
shows the source of
Table
7.3. Reading
Datasheet

Related parts for EVB9311