EVB9311 SMSC, EVB9311 Datasheet - Page 424

EVALUATION BOARD LAN9311-NU

EVB9311

Manufacturer Part Number
EVB9311
Description
EVALUATION BOARD LAN9311-NU
Manufacturer
SMSC
Series
0133r
Datasheet

Specifications of EVB9311

Main Purpose
Interface, Ethernet
Embedded
No
Utilized Ic / Part
LAN9311
Primary Attributes
2 Ports, 100BASE-TX/10BASE-T, Managed
Secondary Attributes
2 PHYs with HP Auto-MDIX, Auto- Flow Control, 32-bit CRC, MDI/MDI-X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1076
Revision 1.7 (06-29-10)
14.5.4.13
31:22
BITS
21
20
19
18
RESERVED
Insert Tag Port 2
When set, untagged packets will have a tag added that contains the Default
VLAN ID and Priority of the ingress port.
The un-tag bit in the VLAN table for the default VLAN ID also needs to be
cleared in order for the tag to be inserted.
This is only used when the Egress Port Type is set as Hybrid.
Change VLAN ID Port 2
When set, regular tagged packets will have their VLAN ID overwritten with
the Default VLAN ID of the egress port.
The Change Tag bit also needs to be set.
The un-tag bit in the VLAN table for the incoming VLAN ID also needs to be
cleared, otherwise the tag will be removed instead.
Priority tagged packets will have VLAN ID overwritten with the Default VLAN
ID of the ingress port independent of this bit.
This is only used when the Egress Port Type is set as Hybrid.
Change Priority Port 2
When set, regular tagged packets will have their Priority overwritten with the
Default Priority of the egress port. Priority tagged packets will have VLAN ID
overwritten with the Default VLAN ID of the ingress port.
For regular tagged packets, the Change Tag bit also needs to be set.
The un-tag bit in the VLAN table for the incoming VLAN ID also needs to be
cleared, otherwise the tag would be removed instead.
This is only used when the Egress Port Type is set as Hybrid.
Change Tag Port 2
When set, allows the Change Tag and Change Priority bits to affect regular
tagged packets.
This bit has no affect on priority tagged packets.
This is only used when the Egress Port Type is set as Hybrid.
Buffer Manager Egress Port Type Register (BM_EGRSS_PORT_TYPE)
This register is used to configure the egress VLAN tagging rules. See
Removing, and Changing VLAN Tags," on page 79
Register #:
1C0Ch
DESCRIPTION
DATASHEET
424
Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface
Size:
for additional details.
32 bits
TYPE
Section 6.5.6, "Adding,
R/W
R/W
R/W
R/W
SMSC LAN9311/LAN9311i
RO
DEFAULT
Datasheet
0b
0b
0b
0b
-

Related parts for EVB9311