EVB9311 SMSC, EVB9311 Datasheet - Page 250

EVALUATION BOARD LAN9311-NU

EVB9311

Manufacturer Part Number
EVB9311
Description
EVALUATION BOARD LAN9311-NU
Manufacturer
SMSC
Series
0133r
Datasheet

Specifications of EVB9311

Main Purpose
Interface, Ethernet
Embedded
No
Utilized Ic / Part
LAN9311
Primary Attributes
2 Ports, 100BASE-TX/10BASE-T, Managed
Secondary Attributes
2 PHYs with HP Auto-MDIX, Auto- Flow Control, 32-bit CRC, MDI/MDI-X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1076
Revision 1.7 (06-29-10)
BITS
6
5
4
3
2
1
0
MF Preamble Suppression
This bit indicates whether the Virtual PHY accepts management frames with
the preamble suppressed.
0: Management frames with preamble suppressed not accepted
1: Management frames with preamble suppressed accepted
Auto-Negotiation Complete
This bit indicates the status of the Auto-Negotiation process.
0: Auto-Negotiation process not completed
1: Auto-Negotiation process completed
Remote Fault
This bit indicates if a remote fault condition has been detected.
0: No remote fault condition detected
1: Remote fault condition detected
Auto-Negotiation Ability
This bit indicates the status of the Virtual PHY’s auto-negotiation.
0: Virtual PHY is unable to perform auto-negotiation
1: Virtual PHY is able to perform auto-negotiation
Link Status
This bit indicates the status of the link.
0: Link is down
1: Link is up
Jabber Detect
This bit indicates the status of the jabber condition.
0: No jabber condition detected
1: Jabber condition detected
Extended Capability
This bit indicates whether extended register capability is supported.
0: Basic register set capabilities only
1: Extended register set capabilities
Note 14.17 The reserved bits 31-16 are used to pad the register to 32-bits so that each register is on
Note 14.18 The Virtual PHY supports 100BASE-X (half and full duplex) and 10BASE-T (half and full
Note 14.19 The Virtual PHY does not support Register 15 or 1000 Mb/s operation. Thus this bit is
Note 14.20 The Auto-Negotiation Complete bit is first cleared on a reset, but set shortly after (when
Note 14.21 The Virtual PHY never has remote faults, its link is always up, and does not detect jabber.
Note 14.22 The VIrtual PHY supports basic and some extended register capability. The Virtual PHY
a DWORD boundary. When accessed serially (through the MII management protocol), the
register is 16-bits wide.
duplex) only. All other modes will always return as 0 (unable to perform).
always returned as 0.
the Auto-Negotiation process is run). Refer to
Negotiation," on page 96
supports Registers 0-6 (per the IEEE 802.3 specification).
DESCRIPTION
DATASHEET
for additional details.
250
Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface
Section 7.3.1, "Virtual PHY Auto-
TYPE
SMSC LAN9311/LAN9311i
RO
RO
RO
RO
RO
RO
RO
Note 14.20
Note 14.21
Note 14.21
Note 14.21
Note 14.22
DEFAULT
Datasheet
0b
1b
0b
1b
1b
0b
1b

Related parts for EVB9311