EVB9311 SMSC, EVB9311 Datasheet - Page 76

EVALUATION BOARD LAN9311-NU

EVB9311

Manufacturer Part Number
EVB9311
Description
EVALUATION BOARD LAN9311-NU
Manufacturer
SMSC
Series
0133r
Datasheet

Specifications of EVB9311

Main Purpose
Interface, Ethernet
Embedded
No
Utilized Ic / Part
LAN9311
Primary Attributes
2 Ports, 100BASE-TX/10BASE-T, Managed
Secondary Attributes
2 PHYs with HP Auto-MDIX, Auto- Flow Control, 32-bit CRC, MDI/MDI-X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1076
Revision 1.7 (06-29-10)
6.4.10.2
6.4.11
Note: The maximum size tagged packet that can normally be sent into a switch port (from the Host
Packets to the Host CPU
The
add the special VLAN tag in packets to the host CPU as a source port indicator. A setting of 11b should
be used only on the port that is connected to the host CPU (typically Port 0). Other settings can be
used on the normal network ports as needed.
The special VLAN tag is a normal VLAN tag where bits 0 and 1 of the VID field specify the source
port (0, 1, or 2).
Upon egress from the host CPU port, the special tag is added. If a regular VLAN tag already exists,
it is not deleted. Instead it will follow the special tag.
Note: Since the special tag adds four bytes to the length of the packet, it is possible for a normally
Note: Since the special tag adds four bytes to the length of the packet, it is possible for a normally
Counters
A counter is maintained per port that contains the number of MAC address that were not learned or
were overwritten by a different address due to MAC Address Table space limitations. These counters
are accessible via the following registers:
A counter is maintained per port that contains the number of packets filtered at ingress. This count
includes packets filtered due to broadcast throttling, but does not include packets dropped due to
ingress rate limiting. These counters are accessible via the following registers:
Switch Engine Port 0 Learn Discard Count Register (SWE_LRN_DISCRD_CNT_MII)
Switch Engine Port 1 Learn Discard Count Register (SWE_LRN_DISCRD_CNT_1)
Switch Engine Port 2 Learn Discard Count Register (SWE_LRN_DISCRD_CNT_2)
Switch Engine Port 0 Ingress Filtered Count Register (SWE_FILTERED_CNT_MII)
Switch Engine Port 1 Ingress Filtered Count Register (SWE_FILTERED_CNT_1)
Switch Engine Port 2 Ingress Filtered Count Register (SWE_FILTERED_CNT_2)
Buffer Manager Egress Port Type Register (BM_EGRSS_PORT_TYPE)
MAC) is 1522 bytes. Since the special tag consumes four bytes of the packet length, the
outgoing packet is limited to 1518 bytes, even if it contains a regular VLAN tag as part of the
packet data. If a larger outgoing packet is required, the Jumbo2K bit in the
Configuration Register (MAC_RX_CFG_x)
tagged, maximum size, incoming packet to become 1526 bytes in length. In order for the Host
MAC to receive this length packet without indicating a length error, the
Register (HMAC_VLAN2)
Tag Register (HMAC_VLAN1)
will allow frames up to 1538 bytes in length to be received.
tagged, maximum size, incoming jumbo packet to become 2052 bytes in length. This packet
will be received by the Host MAC with the following conditions:
The receive status will indicate Frame Too Long
Up to four bytes of the end of packet may be truncated (the maximum receive length at the
Host MAC is 2048).
in the Host MAC should be set to 8100h and the
DATASHEET
should be set to a value other than 8100h. This configuration
76
Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface
of Port 0 should be set.
configures the switch to
SMSC LAN9311/LAN9311i
Host MAC VLAN2 Tag
Port x MAC Receive
Host MAC VLAN1
Datasheet

Related parts for EVB9311