EVB9311 SMSC, EVB9311 Datasheet - Page 75

EVALUATION BOARD LAN9311-NU

EVB9311

Manufacturer Part Number
EVB9311
Description
EVALUATION BOARD LAN9311-NU
Manufacturer
SMSC
Series
0133r
Datasheet

Specifications of EVB9311

Main Purpose
Interface, Ethernet
Embedded
No
Utilized Ic / Part
LAN9311
Primary Attributes
2 Ports, 100BASE-TX/10BASE-T, Managed
Secondary Attributes
2 PHYs with HP Auto-MDIX, Auto- Flow Control, 32-bit CRC, MDI/MDI-X
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1076
Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface
Datasheet
SMSC LAN9311/LAN9311i
6.4.9
6.4.10
6.4.10.1
Note: Most forwarding rules are skipped when a packet is monitored. However, a packet is still filtered
Port Mirroring
The LAN9311/LAN9311i supports port mirroring where packets received or transmitted on a port or
ports can also be copied onto another “sniffer” port.
Port mirroring is configured using the
Multiple mirrored ports can be defined, but only one sniffer port can be defined.
When receive mirroring is enabled, packets that are forwarded from a port designated as a mirrored
port are also transmitted by the sniffer port. For example, Port 2 is setup to be a mirrored port and
Port 0 is setup to be the sniffer port. If a packet is received on Port 2 with a destination of Port 1, it
is forwarded to both Port 1 and Port 0.
When transmit mirroring is enabled, packets that are forwarded to a port designated as a mirrored port
are also transmitted by the sniffer port. For example, Port 2 is setup to be a mirrored port and Port 0
is setup to be the sniffer port. If a packet is received on Port 1 with a destination of Port 2, it is
forwarded to both Port 2 and Port 0.
Note: A packet will never be transmitted out of the receiving port. A receive packet is not normally
Host CPU Port Special Tagging
The
Egress Port Type Register (BM_EGRSS_PORT_TYPE)
used by the host CPU. This special tag is used to specify the port(s) where packets from the CPU
should be sent, and to indicate which port received the packet that was forwarded to the CPU.
Packets from the Host CPU
The
use the special VLAN tag in packets from the host CPU as a destination port indicator. A setting of
11b should be used on the port that is connected to the host CPU (typically Port 0). A setting of 00b
should be used on the normal network ports.
The special VLAN tag is a normal VLAN tag where the VID field is used as the destination port
indicator. If VID bit 3 is zero, then bits 0 and 1 specify the destination port (0, 1, 2) or broadcast (3).
If VID bit 3 is one, then the normal ALR lookup is performed and learning is performed on the source
address. The PRI field from the VLAN tag is used as the packet priority.
Upon egress from the destination port(s), the special tag is removed. If a regular VLAN tag needs to
be sent as part of the packet, then it should be part of the packet data from the host CPU port or set
as an unused bit in the VID field.
Note: When specifying Port 0 as the destination port, the VID will be set to 0. A VID of 0 is normally
Switch Engine Ingress Port Type Register (SWE_INGRSS_PORT_TYP)
Switch Engine Ingress Port Type Register (SWE_INGRSS_PORT_TYP)
if:
mirrored if it is filtered. This can optionally be enabled.
considered a priority tagged packet. Such a packet will be filtered if Admit Only VLAN is set
on the host CPU port. Either avoid setting Admit Only VLAN on the host CPU port or set an
unused bit in the VID field.
The source port is not in the forwarding state (unless Spanning Tree Port State Override is in
VLAN’s are enabled, the packet is untagged or priority tagged, and the Admit Only VLAN bit
VLAN’s are enabled and the packet is tagged and had a VID equal to FFFh.
VLAN’s are enabled, Enabled Membership Checking on Ingress is set, Admit Non Member is
effect.
for the ingress port is set.
cleared, and the source port is not a member of the incoming VLAN.
DATASHEET
Switch Engine Port Mirroring Register
75
are used to enable a special VLAN tag that is
(SWE_PORT_MIRROR).
configures the switch to
and
Revision 1.7 (06-29-10)
Buffer Manager