ibm3206k0424 ETC-unknow, ibm3206k0424 Datasheet - Page 408

no-image

ibm3206k0424

Manufacturer Part Number
ibm3206k0424
Description
Ibm Processor For Network Resources
Manufacturer
ETC-unknow
Datasheet
IBM3206K0424
IBM Processor for Network Resources
The PHY Interface (LINKC)
Page 408 of 676
21-20
18-16
15-13
Bit(s)
19
18
17
16
12
11
10
9
Number of Additional Header
Bytes
Modify byte alignment in 16-bit
PHY mode
Bits 18-16 only have meaning if a PMC PM5346 SUNI LITE/UTOPIA (bits 31-29 = "011") is selected. If any other device is
chosen, these bits will be ignored.
52 Byte Cell
Disable HEC Generation on
Transmitted Cells
Parity on all 16 bits
PHY Receive Device
Enable Parity Checking
Even/Odd Parity Selection
PHY Data Path Size
16 bit parity
Name
These bits indicate the number of additional header bytes that will be read from SEG-
BUF and added to the beginning of each cell as each is transmitted to the PHY. The
bytes are meant to be used for additional routing information. These control bits have
no affect in IBM 25 Mb/s PHY mode, and should be set to ’0’s when in internal
SONET/SDH framer mode. If used in conjunction with 52-byte mode, the byte normally
containing the cell HEC will not be transmitted and the total number of cells transmitted
will be the value of this field plus 52. If 16-bit PHY mode is selected, by default, the
byte alignment will follow that of normal 52- or 53-byte 16-bit mode, with the additional
header bytes contiguously prepended. As a result, a mode with three additional header
bytes cannot be obtained in 53-byte, 16-bit mode (LSB is normally padded with zeros
so MSB gets truncated). Bit 3 of this register is therefore provided to adjust the align-
ment in 16-bit, 53-byte mode so all five header bytes will be transmitted with up to
three additional router bytes prepended.
When set to ’1’, this bit changes the default byte alignment in 16-bit PHY mode if this
register also contains a non-zero value in bits 21-20. See the description of those bits
for further details.
When set, the cell sent to the PHY will be 52 bytes. No HEC byte will be sent.
If bit 17 is set to ’1’, X'00' will be placed in the HEC byte of Utopia cells. If bit 17 is set
to ’0’, then the value of LINKC Transmitted HEC Control byte will be sent. If bit 18 is set
to ’1’, then no HEC will be sent and this bit will be ignored.
When set, this bit enables the IBM3206K0424 to produce a single parity bit across the
16-bit transmit data bus. When set to ’0’, the IBM3206K0424 will produce two parity
bits, one across generation and the lower half of the 16 bits (parity bit 0) and one
against the upper (parity bit 1). The default for this bit is ’1’.
These bits indicate to which PHY the IBM3206K0424’s Receive Config 0 will be inter-
facing. If the configuration's port address is all ‘1’s, then the configuration is unused
and the value of the above bits doesn't matter.
'000'
'001'
'010’ Reserved
'011'
'100'
'101'
'111'
When set, this bit will enable checking of parity on data from the receive path. The
default is parity checking is disabled. The upper bit of the transmit parity is not valid
when the internal SONET/SDH Framer has been selected as the receive PHY device.
The upper bit of the receive parity is also not valid when the internal SONET/SDH
Framer has been selected as the transmit PHY device. This is only a concern if a com-
bination of the internal framer and an external PHY is being used and that external
PHY has a 16-bit data interface. In this case, parity cannot be checked/generated on
the upper byte.
Even parity is selected when this bit is cleared. The default value is for odd parity.
This bit, when set to ’0’, selects a 16-bit wide data path to the PHY device. When set to
’1’, the data path width to the PHY will be eight bits. This bit has no affect on the inter-
nal SONET/SDH framer except if the internal framer has been selected as the Rx PHY
device but not as the Tx PHY device. In this case, a ’1’ on this bit will allow FYT-
DAT(15-13) to be used for the 16-bit external Tx PHY device, while a zero will allow
FYTDAT(15-13) to be used for the Rx HDLC controller. This implies that it is not possi-
ble to use the internal RX framer, the RX HDLC interface, and an external 16-bit TX
framer at the same time.
When this bit is set to ’1’ in 16-bit mode, parity will be calculated across all 16 bits and
checked against FYRPAR(1). When in 8-bit mode with bit 9 set to ’0’, the parity will be
compared against FYRPAR(1). This bit has no affect if receive device is POS-PHY.
The default setting of this bit is ’1’.
Reserved
PMC POS-PHY (Frame-based Utopia)
PMC PM5346 SUNI LITE/UTOPIA interface (STS-3c/STM-1 OR STS-1)
Reserved
Internal SONET (sts-3c)/SDH(STM-1) Framer with SERDES (Serial Interface)
Reserved
Description
pnr25.chapt05.01
August 14, 2000
Preliminary