DS3112+W Maxim Integrated Products, DS3112+W Datasheet - Page 59

IC MUX T3/E3 3.3V 256-PBGA

DS3112+W

Manufacturer Part Number
DS3112+W
Description
IC MUX T3/E3 3.3V 256-PBGA
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS3112+W

Controller Type
Framer, Multiplexer
Interface
Parallel/Serial
Voltage - Supply
3.135 V ~ 3.465 V
Current - Supply
150mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
256-PBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
5.6 T3/E3 Performance Error Counters
There are six error counters in the DS3112. All of the errors counters are 16 bits in length. The host has
three options as to how these errors counters are updated. The device can be configured to automatically
update the counters once a second or manually via either an internal software bit (MECU) or an external
signal (FRMECU). See Section
rollover.
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit #
Name
Default
Note: Bits that are underlined are read-only; all other bits are read-write.
Bits 0 to 15: 16-Bit BiPolar Violation Counter (BPV0 to BPV15). These bits report the number of BiPolar
Violations (BPV). In the E3 Mode, this counter can also be configured via the E3CVE bit in the T3E3 Control
Register (Section 5.2) to count Code Violations (CV). A BPV is defined as consecutive pulses (or marks) of the
same polarity that are not part of a B3ZS/HDB3 codeword. A CV is defined in ITU O.161 as consecutive BPVs of
the same polarity.
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit #
Name
Default
Note: Bits that are underlined are read-only; all other bits are read-write.
Bits 0 to 15: 16-Bit EXcessive Zero Counter (EXZ0 to EXZ15). These bits report the number of EXcessive Zero
occurrences (EXZ). An EXZ occurrence is defined as three or more consecutive zeros in the T3 mode and four or
more consecutive zeros in the E3 mode. As an example, a string of eight consecutive zeros would only increment
this counter once.
BPV15
EXZ15
BPV7
EXZ7
15
15
7
7
BPV14
EXZ14
BPV6
EXZ6
14
14
6
6
BPVCR
BiPolar Violation Count Register
20h
EXZCR
EXcessive Zero Count Register
22h
4.2
BPV13
EXZ13
BPV5
EXZ5
for details. All the error counters saturate when full and will not
13
13
5
5
BPV12
EXZ12
59 of 133
BPV4
EXZ4
12
12
4
4
BPV11
EXZ11
BPV3
EXZ3
11
11
3
3
BPV10
EXZ10
BPV2
EXZ2
10
10
2
2
BPV1
BPV9
EXZ1
EXZ9
1
9
1
9
BPV0
BPV8
EXZ0
EXZ8
DS3112
0
8
0
8

Related parts for DS3112+W