peb2255 Infineon Technologies Corporation, peb2255 Datasheet - Page 35

no-image

peb2255

Manufacturer Part Number
peb2255
Description
E1/t1/j1 Framer And Line Interface Component For Long And Short Haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
peb22554H/T
Manufacturer:
INF
Quantity:
5 510
Part Number:
peb22554H/T
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
peb22554HT
Manufacturer:
INFINEON
Quantity:
325
Part Number:
peb22554HT V1.3
Quantity:
1 078
Part Number:
peb22554HT V1.3
Manufacturer:
Infineon
Quantity:
490
Part Number:
peb22554HT2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554HTV1.3
Manufacturer:
INFIEON
Quantity:
20 000
Part Number:
peb22554HTV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb22554V1.3
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
peb2255H
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Table 4
Pin No.
57
70
Data Sheet
Symbol
RDO
DLR
RSIG
Pin Definitions - System Interface
Input (I)
Output (O)
Supply (S)
O
O
O
System Interface Receive
Function
Receive Data Out
Received data which is sent to the system
highway at 4096 kbit/s, 2048 kbit/s or
1544 kbit/s (T1/J1 only). In 4096 kbit/s mode
data is shifted out in the channel phase which is
selected by RC0.SICS. During the other channel
phase RDO is set into tristate.
Clocking off data is done with the falling edge of
SCLKR or RCLK, if the receive elastic store is
bypassed. The delay between the beginning of
time-slot 0 and the initial edge of SCLKR (after
SYPR goes active) is determined by the values
of registers RC1 and RC0.
Data Link Bit Receive
E1 mode:
Marks the S
RDO. The S
every frame not containing the frame alignment
signal are selected by register XC0.SA4E-
SA8E.
T1/J1 mode:
Provides a signal which marks the DL bit
position within the data stream on RDO. It can
be used as receive strobe signal for external
data link controllers. In 4096 kbit/s mode DLR is
active only during the channel phase selected by
RCO.SICS.
Receive Signaling Data
Output for receive signaling data sent to the
signaling highway.
This function is selected by setting
LOOP.SPN = 1
LIM3.ESY = 1
XSP.CASEN = 0
35
A
A
4...8 bits within the data steam on
4...8 bit positions in time slot 0 of
Pin Descriptions
FALC-LH V1.3
PEB 2255
2000-07