TMPM330FWFG Toshiba, TMPM330FWFG Datasheet - Page 381
TMPM330FWFG
Manufacturer Part Number
TMPM330FWFG
Description
Microcontrollers (MCU) MCU w/ ARM Cortex-M3 128K FLASH, 8K SRAM
Manufacturer
Toshiba
Specifications of TMPM330FWFG
Processor Series
TX03
Core
ARM Cortex M3
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
128K
Rom Type
Flash
Ram (kbytes)
8K
Number Of Pins
100
Package
LQFP(14×14)
Vcc
3V
Cpu Mhz
40
Ssp (ch) Spi
-
I2c/sio (ch)
3
Uart/sio (ch)
3
Usb
-
Can
-
Ethernet
-
External Bus Interface
-
Cs/wait Controller (ch)
-
Dma Controller
-
10-bit Da Converter
-
10-bit Ad Converter
12
12-bit Ad Converter
-
16-bit Timer / Counter
10
Motor / Igbt Control
-
Real Time Clock
1
Watchdog Timer
Y
Osc Freq Detect
-
Clock Gear
Y
Low-power Hold Function
-
Remote Control Interface
Y
Hardware Cec Controller
Y
Comparators
-
Low-voltage Detector
-
Etm Hardware Trace
4-bit
Lead Free Status / Rohs Status
Details
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
- Current page: 381 of 528
- Download datasheet (6Mb)
(3)
Remote Control Signal in a Phase Method".
Threshold of 0/1
determination
detemination
result
Based on a falling edge cycle, the data bit is determined as 0 or 1.
There are two kinds of determinations:
The followings shows the determination model of data bit.
As for data bit determination of a remote control signal in a phase method, see"13.4.1.8 Receiving a
Setting of 0/1 determination data bit
Data bit
waveform
Threshold of 0/1 detemination is set to 2.5T with the <RMCDATL[6:0]>bit.
1. Determination by threshold.
2. Determination by falling edge interrupt inputs.
bit as "0" or "1." If the determination value is equal to threshold value or more, it is determined
as "1." If the determination value is less than threshold value, it is determined as "0."
edge interrupt can be generated in each falling edge of the data bit. Using this interrupt together
with a timer enables the determination to be done by software.
Configure a threshold value to RMCxRCR3<RMCDATL[6:0]> bit which determines data
By setting "1" to the RMCxRCR2<RMCEDIEN> bit, a remote control signal input falling
T
T
Remote control input falling edge interrupt
T
Page 361
"0"
T
T
T
"1"
T
T
TMPM330FDFG/FYFG/FWFG
"0"
T
T
Related parts for TMPM330FWFG
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
AC/DC Power Modules
Manufacturer:
TRACOPOWER
Datasheet:
Part Number:
Description:
AC/DC Power Modules
Manufacturer:
TRACOPOWER
Datasheet:
Part Number:
Description:
AC/DC Power Modules
Manufacturer:
TRACOPOWER
Datasheet:
Part Number:
Description:
AC/DC Power Modules
Manufacturer:
TRACOPOWER
Datasheet:
Part Number:
Description:
AC/DC Power Modules
Manufacturer:
TRACOPOWER
Datasheet: