CS1D-DPL02D Omron, CS1D-DPL02D Datasheet - Page 99

no-image

CS1D-DPL02D

Manufacturer Part Number
CS1D-DPL02D
Description
CS1D Dual IO Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-DPL02D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
File Memory
Using EM File Memory
Operation in a Duplex CPU
System
EM File Memory-related
Functions
2-5-2
General-use Files
Files Transferred
Automatically at Startup
64
Writing to EM file
memory by FWRIT
instruction
Reading from EM file
memory by FREAD
instruction
Function
Files Handled by CPU Unit
Accessed.
CPU Unit
In active
EM file memory
Note For details, refer to the CS/CJ-series Programming Manual.
Note If EM file memory is specified for the active CPU Unit’s EM Area with the PLC
When a file is written to the EM file memory in the active CPU Unit in a Duplex
System, the same file is simultaneously written to the EM file memory in the
standby CPU Unit.
Setup, the same banks will be specified for the standby CPU Unit’s EM Area
by means of duplex initialization.
The following table shows the operations of the EM file memory-related func-
tions.
Files are ordered and stored in the Memory Card or EM file memory accord-
ing to the file name and the extension attached to it. File names handled by
the CPU Unit (i.e., file names that can be read) are set as shown in the follow-
ing tables.
Data files
Program files
Parameter files
Data files
Accessed
Not
accessed.
In standby
CPU Unit
File type
File type
When a file is written to the active CPU
Unit’s EM file memory, the file is simul-
taneously written to the standby CPU
Unit’s EM file memory. FWRIT instruc-
tion execution is synchronized for the
active and standby CPU Units.
The FREAD instruction is executed for
both CPU Units, and the data read
from the active CPU Unit’s EM file
memory is used by both CPU Units.
Specified range in I/O
memory
All user programs
PLC Setup, registered I/O tables,
routing tables, CPU Bus Unit set-
tings, SYSMAC LINK link tables, and
Controller Link link tables
DM Area data (stores data for
specified number of words starting
from D20000)
DM Area data (stores data for
specified number of words starting
from D00000)
EM area for bank No. @ (stores
data for specified number of words
starting from E@_00000)
Data matching method
Contents
Contents
Binary
Text
CSV
AUTOEXEC
ATEXECDM
ATEXECE@
(EM bank No.)
When referencing file mem-
ory-related status, use the
status for the active CPU Unit
(word A343).
File name
Note
Section 2-5
.IOM
.IOM
.IOM
.IOM
.TXT
.CSV
.OBJ
.STD
File name
Extension