CS1D-DPL02D Omron, CS1D-DPL02D Datasheet - Page 573

no-image

CS1D-DPL02D

Manufacturer Part Number
CS1D-DPL02D
Description
CS1D Dual IO Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-DPL02D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
538
Auxiliary Area Allocations
A512 to
A513
A514
A515 to
A517
A518 to
A520
A523
Word
Addresses
A51200
to
A51315
A51400
to
A51415
A52300
to
A52315
Bit
Power
Interrup-
tion Time
Number of
Power
Interrup-
tions
Operation
Start Time
Operation
End Time
Total
Power ON
Time
Name
These words contain the time at which
the power was interrupted. The con-
tents are updated every time that the
power is interrupted. The data is stored
in BCD.
A51200 to A51207: Second (00 to 59)
A51208 to A51215: Minute (00 to 59)
A51300 to A51307: Hour (00 to 23)
A51308 to A51315: Day of month (01 to
31)
(These words are not cleared at start-
up.)
Contains the number of times that
power has been interrupted since the
power was first turned ON. The data is
stored in binary. To reset this value,
overwrite the current value with 0000.
(This word is not cleared at start-up, but
it is cleared when the Memory Corrup-
tion Detected Flag (A39511) goes ON.)
The time that operation started as a
result of changing the operating mode
to RUN or MONITOR mode is stored
here in BCD.
A51500 to A51507: Seconds (00 to 59)
A51508 to A51515: Minutes (00 to 59)
A51600 to A51607: Hour (00 to 23)
A51608 to A51615: Day of month (01 to
31)
A51700 to A51707: Month (01 to 12)
A51708 to A51715: Year (00 to 99)
Note: The previous start time is stored
The time that operation stopped as a
result of changing the operating mode
to PROGRAM mode is stored here in
BCD.
A51800 to A51807: Seconds (00 to 59)
A51808 to A51815: Minutes (00 to 59)
A51900 to A51907: Hour (00 to 23)
A51908 to A51915: Day of month (01 to
31)
A52000 to A52007: Month (01 to 12)
A52008 to A52015: Year (00 to 99)
Note: If an error occurs in operation,
Contains the total time that the PLC has
been on in 10-hour units. The data is
stored in binary and it is updated every
10 hours. To reset this value, overwrite
the current value with 0000. Once the
value reaches FFFF, it will not be
updated further and will remain at FFFF
until reset.
(This word is not cleared at start-up, but
it is cleared to 0000 when the Memory
Corruption Detected Flag (A39511)
goes ON.)
after turning ON the power sup-
ply until operation is started.
the time of the error will be
stored. If the operating mode is
then changed to PROGRAM
mode, the time that PROGRAM
mode was entered will be stored.
Function
See Function
column.
0000 to FFFF
hex
See at left.
See at left.
0000 to FFFF
hex
Settings
Held
Held
Retained Retained See at
Retained Retained See at
Held
change
Status
mode
after
Status at
Held
Held
Held
startup
Written at
power
interrup-
tion
When
power is
turned
ON
left.
left.
---
Timing
Appendix B
---
A39511
---
---
---
Settings
Related
Flags,

Related parts for CS1D-DPL02D