CS1D-DPL02D Omron, CS1D-DPL02D Datasheet - Page 548

no-image

CS1D-DPL02D

Manufacturer Part Number
CS1D-DPL02D
Description
CS1D Dual IO Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-DPL02D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Auxiliary Area Allocations
A272
A273
A294
A295
Words
Address
A27215
---
A27300
A27301
A27302
A27303
A27304
A27305
A27306
A27307
A27308
A27309
All
A29508
A29509
Bits
Online
Addition
Failed Flag
Online
Addition
Failure
Cause
Flags
Task Num-
ber when
Program
Stopped
Instruc-
tion Pro-
cessing
Error Flag
Indirect
DM/EM
BCD Error
Flag
Name
ON: An error occurred that pre-
vented a Backplane and Unit from
being added online.
When an error occurred that pre-
vented a Backplane and Unit from
being added online, the relevant flag
will be turned ON.
Transmitted I/O tables are invalid
(changed or deleted).
Basic I/O Unit mounted in an invalid
slot.
No Unit mounted in the added slot.
Specified an Expansion Backplane
addition to an earlier CPU Back-
plane version.
A CPU Bus Unit was added.
The added Unit's model is different
from the Unit that was specified to
be mounted.
The added Basic I/O Unit's allocated
words duplicate the words of an
existing Unit.
The added unit number duplicates
an existing unit number.
The number of I/O points exceeds
the maximum (5,120 I/O points).
There is an error in the added
Expansion Backplane (power supply
OFF).
This word contains the task number
of the task that was being executed
when program execution was
stopped because of a program error.
(A298 and A299 contain the pro-
gram address where program exe-
cution was stopped.)
This flag and the Error Flag (ER) will
be turned ON when an instruction
processing error has occurred and
the PLC Setup has been set to stop
operation for an instruction error.
CPU Unit operation will stop and the
ERR/ALM indicator will light when
this flag goes ON.
(The task number where the error
occurred will be stored in A294 and
the program address will be stored
in A298 and A299.)
This flag and the Access Error Flag
(AER) will be turned ON when an
indirect DM/EM BCD error has
occurred and the PLC Setup has
been set to stop operation an indi-
rect DM/EM BCD error. (This error
occurs when the content of an indi-
rectly addressed DM or EM word is
not BCD although BCD mode has
been selected.) CPU Unit operation
will stop and the ERR/ALM indicator
will light when this flag goes ON.
(The task number where the error
occurred will be stored in A294 and
the program address will be stored
in A298 and A299.)
Function
OFF
An error pre-
vented a Back-
plane or Unit
from being
added online.
OFF
The correspond-
ing error pre-
vented a
Backplane or
Unit from being
added online.
Normal tasks:
0000 to 001F
(task 0 to 31)
ON: Error Flag
ON
OFF: Error Flag
OFF
ON: Not BCD
OFF: Normal
Settings
ON:
ON:
Cleared
Cleared
Cleared
Cleared
Cleared
change
Status
mode
after
Cleared
Cleared
Cleared
Cleared
Cleared
Status at
startup
Each
cycle
Each
cycle
---
---
---
Timing
Appendix B
---
---
A298/
A299
A294,
A298/
A299
PLC
Setup
(Opera-
tion
when in-
struction
error has
oc-
curred)
A294,
A298/
A299
PLC
Setup
(Opera-
tion
when in-
struction
error has
oc-
curred)
settings
Related
flags,
513

Related parts for CS1D-DPL02D