CS1D-DPL02D Omron, CS1D-DPL02D Datasheet - Page 63

no-image

CS1D-DPL02D

Manufacturer Part Number
CS1D-DPL02D
Description
CS1D Dual IO Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-DPL02D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Specifications
28
Serial communica-
tions
Clock
Power OFF detection
time
Power OFF detection
delay time
Memory protection
Sending commands to
a Host Link computer
Remote programming
and monitoring
Multiple-level commu-
nications
Storing comments in
CPU Unit
Program check
Control output signals RUN output: An internal contact turns ON when the CPU
Battery service life
Self-diagnostics
Other functions
Function
Built-in peripheral port: Programming Device (including
Programming Console) connections, Host Links, NT Links
Built-in RS-232C port: Programming Device (excluding Pro-
gramming Console) connections, Host Links, no-protocol
communications, NT Links
Serial Communications Board (sold separately): Protocol
macros, Host Links, NT Links
Provided on all models. Accuracy:
10 to 25 ms (AC power supply)
2 to 5 ms (DC power supply)
0 to 10 ms (user-defined, default: 0 ms)
Held Areas: Holding bits, contents of Data Memory and
Extended Data Memory, and status of the counter Comple-
tion Flags and present values.
Note If the IOM Hold Bit in the Auxiliary Area is turned
FINS commands can be sent to a computer connected via
the Host Link System by executing Network Communica-
tions Instructions from the PLC.
Host Link communications can be used for remote pro-
gramming and remote monitoring through a Controller Link
System or Ethernet network.
Duplex CPU Systems: 3 levels
Single CPU Systems: 8 levels
Note Communications are possible across up to eight lev-
I/O comments can be stored in the CPU Unit in Memory
Cards or EM file memory.
Program checks are performed at the beginning of opera-
tion for items such as no END instruction and instruction
errors.
CX-Programmer can also be used to check programs.
Unit is operating in RUN or MONITOR mode.
These terminals are provided only on CS1D-PA207R
Power Supply Units.
Battery Set: CS1W-BAT01
CPU errors (watchdog timer), I/O verification errors, I/O bus
errors, memory errors, and battery errors
Storage of number of times power has been interrupted.
(Stored in A514.)
Note a) The accuracy varies with the temperature.
ON, and the PLC Setup is set to maintain the IOM
Hold Bit status when power to the PLC is turned
ON, the contents of the CIO Area, the Work Area,
part of the Auxiliary Area, timer Completion Flags
and PVs, Index Registers, and the Data Registers
will be saved.
els only for the Controller Link and Ethernet net-
works (and the CX-Integrator or CX-Net in CX-
Programmer version 4.0 or higher is required to set
the routing tables). Communications are possible
across only up to three communications levels for
the SYSMAC LINK, DeviceNet, and FL-net net-
works.
b) Used to store the time when power is turned
ON and when errors occur.
Specifications
30 s/mo. at 25 C
2-6 Programming Devices
Programming Manual (W394)
Programming Manual (W394)
9-3 Power OFF Operation
Programming Manual (W394)
8-2-3 Data Area Properties
---
Programming Manual (W394)
---
I/O comments: CX-Programmer
User Manual
Storing comments in CPU Units:
Programming Manual (W394)
Programming Manual (W394)
Programming Manual (W394)
11-2-1 Battery Replacement
10-2-4 Errors and Troubleshooting
9-3 Power OFF Operation
Reference
Section 2-1