CS1D-DPL02D Omron, CS1D-DPL02D Datasheet - Page 93

no-image

CS1D-DPL02D

Manufacturer Part Number
CS1D-DPL02D
Description
CS1D Dual IO Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-DPL02D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
CPU Units
DIP Switch Pins 4 to 6
58
7
8
4
5
6
4
5
6
Pin No.
Pin No.
Pin No.
Always OFF. ---
Always OFF. Use with this pin set to OFF.
Always OFF. Use with this pin set to OFF.
Always OFF. Use with this pin set to OFF.
ON
OFF
ON
OFF
ON
OFF
Setting
Setting
Setting
!Caution Always touch a grounded metal object to discharge static electricity from your
Simple backup type
Peripheral port communications
parameters set in the PLC Setup
are used.
Peripheral port communications
parameters set using Programming
Console or CX-Programmer
(Peripheral bus only) are used.
RS-232C port communications
parameters set using a CX-Pro-
grammer (Peripheral bus only) are
used.
RS-232C port communications
parameters set in the PLC Setup
are used.
User-defined pin. Turns OFF the
User DIP Switch Pin Flag (A39512).
User-defined pin. Turns ON the
User DIP Switch Pin Flag (A39512).
Note
■ Duplex CPU Systems
■ Single CPU Systems
Set these pins as described below. Settings are different for Duplex CPU and
Single CPU Systems.
body before changing the settings on the DIP switch during operation.
1. When pin 1 is set to ON, writing is prohibited for the user program and all
2. In a Duplex CPU System, automatic transfer at startup can be executed
3. Simple Backup Operations
Function
Function
Function
parameter data (PLC Setup, I/O table registration, etc.). Moreover, it is not
possible to clear the user program or parameters even by executing a
memory clear operation from a Programming Device.
only from the active CPU Unit. Duplex initialization is performed between
the two CPU Units after the automatic transfer, and the user program, pa-
rameters, and I/O memory are matched. If pin 2 it set to ON, I/O memory
(AUTOEXEC.IOM, ATEXEC@@.IOM) will also be transferred automatical-
ly. (Refer to the Programming Manual.) The program (AUTOEXEC.OBJ)
and Parameter Area (AUTOEXEC.STD) must both be on the Memory
Card, but the I/O memory (AUTOEXEC.IOM, ATEXEC@@.IOM) does not
need to be.
In Duplex Mode, the simple backup function can be executed only from the
active CPU Unit. Duplex initialization is not executed between the two CPU
Used to determine the simple backup type. (See
note 3.)
Normally turn this pin OFF.
---
Do not set these switches. Instead, use the
PRPHL and COMM switches on the Duplex Unit
and A39512 in the Auxiliary Area.
Turn ON to use the peripheral port for a device
other than Programming Console or CX-Pro-
grammer (Peripheral bus only).
Turn ON to use the RS-232C port for a Program-
ming Device.
Set pin 6 to ON or OFF and use A39512 in the
program to create a user-defined condition with-
out using an I/O Unit.
Application
Application
Application
Section 2-4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Default
Default
Default