CS1D-DPL02D Omron, CS1D-DPL02D Datasheet - Page 28

no-image

CS1D-DPL02D

Manufacturer Part Number
CS1D-DPL02D
Description
CS1D Dual IO Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-DPL02D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Application Precautions
!WARNING
!Caution Failure to abide by the following precautions could lead to faulty operation of
Always heed these precautions. Failure to abide by the following precautions
could lead to serious or possibly fatal injury.
the PLC or the system, or could damage the PLC or PLC Units. Always heed
these precautions.
• Always turn OFF the reserved pin (RSV) of the Duplex Unit's Communica-
• Never connect pin 6 (5-V power supply) on the RS-232C port on the CPU
• You must use the CX-Programmer (programming software that runs on
• Always connect to a ground of 100
• A ground of 100
• Always turn OFF the power supply to the PLC before attempting any of
• The user program and parameter area data in the CPU Units are backed
• The PLC Setup is set to specify using the mode set on the Programming
• When creating an AUTOEXEC.IOM file from a Programming Device (a
Note The Online Replacement Completed Bit is provided to restart the
tions Setting DIP Switch.
Unit to any device other than an NT-AL001, CJ1W-CIF11 Adapter, or
NV3W-M@20L Programmable Terminal. The external device or the CPU
Unit may be damaged.
Windows) if you need to program more than one task. A Programming
Console can be used to program only one cyclic task. A Programming
Console can, however, be used to edit multitask programs originally cre-
ated with the CX-Programmer.
connecting to a ground of 100
terminals on the Power Supply Unit.
the following. Not turning OFF the power supply may result in malfunction
or electric shock.
up in the built-in flash memory. The BKUP indicator will light on the front
of the CPU Unit when the backup operation is in progress. Do not turn
OFF the power supply to the CPU Unit when the BKUP indicator is lit. The
data will not be backed up if power is turned OFF.
Console and a Programming Console is not connected, the CPU Unit will
start in RUN mode. This is the default setting in the PLC Setup. (A CS1
CPU Unit will start in PROGRAM mode under the same conditions.)
Programming Console or the CX-Programmer) to automatically transfer
data at startup, set the first write address to D20000 and be sure that the
size of data written does not exceed the size of the DM Area. When the
data file is read from the Memory Card at startup, data will be written in
• Mounting or dismounting Power Supply Units, I/O Units, CPU Units, In-
• Assembling the Units.
• Setting DIP switches or rotary switches.
• Connecting cables or wiring the system.
• Connecting or disconnecting the connectors.
ner Boards, or any other Units.
data exchange between the replaced Unit and CPU Unit. After a
Unit has been replaced without a Programming Device, turn ON the
Online Replacement Completed Bit to restart the data exchange.
or less must be installed when shorting the GR and LG
or less may result in electric shock.
or less when installing the Units. Not