Input response time
setting
Startup mode setting
Flash memory
Memory Card func-
tions (Accessed only
for Memory Card
mounted in active
CPU Unit of Duplex
CPU System.)
Filing
Debugging
Online editing
Program protection
Error check
Error log
Function
Time constants can be set for inputs from Basic I/O Units.
The time constant can be increased to reduce the influence
of noise and chattering or it can be decreased to detect
shorter pulses on the inputs.
Supported
The CPU Unit will start in RUN mode if the PLC Setup is set
to use the Programming Console mode (default) and a Pro-
gramming Console is not connected.
The user program and Parameter Area data (e.g., PLC
Setup) are always backed up automatically in flash mem-
ory.
Automatically reading pro-
grams (autoboot) from the
Memory Card when the
power is turned ON.
Program replacement dur-
ing PLC operation.
Format in which data is
stored in Memory Card
Functions for which Memory
Card read/write is supported
Memory Card data and the EM (Extended Data Memory)
Area can be handled as files.
Control set/reset, differential monitoring, data tracing
(scheduled, each cycle, or when instruction is executed),
storing location generating error when a program error
occurs
User programs can be overwritten in program-block units
when the CPU Unit is in MONITOR or PROGRAM mode.
This function is not available for block programming areas.
With the CX-Programmer, more than one program block
can be edited at the same time.
Overwrite protection: Set using DIP switch.
Copy protection: Password set using Programming Device.
User-defined errors (i.e., user can define fatal errors and
non-fatal errors)
The FPD(269) instruction can be used to check the execu-
tion time and logic of each programming block.
FAL and FALS instructions can be used with the CS1-H
CPU Units to simulate errors.
Up to 20 errors are stored in the error log. Information
includes the error code, error details, and the time the error
occurred.
The CPU Unit can be set so that user-defined FAL errors
are not stored in the error log.
Specifications
Supported.
Supported.
User program: Program file
format
PLC Setup and other param-
eters: Data file format
I/O memory: Data file format
(binary format), text format,
or CSV format (except pre-
version-1 CS1 CPU Units)
User program instructions,
Programming Devices
(including Programming
Consoles), Host Link com-
puters, AR Area control bits,
simple backup operation
Input response time: 9-4-8 I/O
Response Time
Input response settings: Program-
ming Manual (W394)
Programming Manual (W394)
6-1 Overview of PLC Setup
---
2-5 File Memory
Programming Manual (W394)
Programming Manual (W394)
Programming Manual (W394)
Programming Manual (W394)
Programming Manual (W394)
Programming Manual (W394)
Programming Manual (W394)
Programming Manual (W394)
Failure diagnosis: Programming
Manual (W394)
Fatal and nonfatal errors: SECTION
10 Troubleshooting
User-defined errors: Programming
Manual (W394)
Programming Manual (W394)
Reference
Section 2-1
27