CS1D-DPL02D Omron, CS1D-DPL02D Datasheet - Page 582

no-image

CS1D-DPL02D

Manufacturer Part Number
CS1D-DPL02D
Description
CS1D Dual IO Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-DPL02D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
A20015: Initial Task Flag
A20015 will turn ON during the first time a task is executed after it has reached executable status. It will be ON
only while the task is being executed and will not turn ON if following cycles.
A20200 to A20207: Communications Port Enabled Flags
A300: Error Record Pointer
Auxiliary Area Allocations
Network communications in-
struction executed for port 0.
Error record 1
Error record 20
A20015
The program is designed so that CMND(490)
will be executed only when A20200 is ON.
A20200
1 cycle
Executable
status
Example
Executed
1
0
A20200
Instruction
execution
Port 0
Port 1
Port 7
Stored
Stored
Stored
next
CMND
Points to the next record to be used.
00 to 14 hex
CMND
SEND
PMCR
Appendix B
547

Related parts for CS1D-DPL02D