CS1D-DPL02D Omron, CS1D-DPL02D Datasheet - Page 577

no-image

CS1D-DPL02D

Manufacturer Part Number
CS1D-DPL02D
Description
CS1D Dual IO Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-DPL02D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
542
Auxiliary Area Allocations
A636
A650
Word
Addresses
A63601
A63602
A63603
A63604
A65000
to
A65007
A65014
A65015
Bit
Communi-
cations
Board
Port 1
Settings
Changing
Flag
Communi-
cations
Board
Port 2
Settings
Changing
Flag
Communi-
cations
Board
Port 3
Settings
Changing
Flag
Communi-
cations
Board
Port 4
Settings
Changing
Flag
Program
Replace-
ment End
Code
(Not sup-
ported by
CS1@-
CPU@@
(-V1)
Units)
Replace-
ment
Error Flag
hex
Replace-
ment Start
Bit hex
Name
The corresponding flag will be ON
when the settings for that port are being
changed.
The flag will be turned ON when
STUP(237) is executed and it will be
turned OFF by an event issued from the
Serial Communications Board after the
settings have been changed.
It is also possible for the user to indi-
cate a change in serial port settings by
turning these flags ON.
(Single CPU Systems only)
• Normal End (i.e., when A65014 is
• Error End (i.e., when A65014 is ON)
• File memory operation
• User program write
• Operating mode change
ON when the Replacement Start Bit
(A65015) is turned ON to replace the
program, but there is an error. If the
Replacement Start Bit is turned ON
again, the Replacement Error Flag will
be turned OFF.
Program replacement starts when the
Replacement Start Bit is turned ON if
the Program Password (A651) is valid
(A5A5 hex). Do not turn OFF the
Replacement Start Bit during program
replacement.
When the power is turned ON or pro-
gram replacement is completed, the
Replacement Start Bit will be turned
OFF, regardless of whether replace-
ment was completed normally or in
error.
It is possible to confirm if program
replacement is being executed by read-
ing the Replacement Start Bit using a
Programming Device, PT, or host com-
puter.
OFF)
01 hex: Program file (.OBJ) replaced.
00 hex: Fatal error
01 hex: Memory error
11 hex: Write-protected
12 hex: Program replacement pass-
21 hex: No Memory Card
22 hex: No such file
23 hex: Specified file exceeds capac-
31 hex: One of the following in
word error
ity (memory error).
progress:
Function
1: Changing
0: Not chang-
ing
1: Changing
0: Not chang-
ing
1: Changing
0: Not chang-
ing
1: Changing
0: Not chang-
ing
---
ON: Replace-
ment error
OFF: No
replacement
error, or the
Replacement
Start Bit
(A65015) is
ON.
ON: Program
replaced
OFF: Replace-
ment com-
pleted, or after
power is turned
ON
Settings
Retained Cleared
Retained Cleared
Retained Cleared
Retained Cleared
Retained Cleared
Held
Held
change
Status
mode
after
Status at
Cleared
Cleared
startup
---
---
---
---
---
---
---
Timing
Appendix B
---
---
---
---
---
---
---
Settings
Related
Flags,