CS1D-DPL02D Omron, CS1D-DPL02D Datasheet - Page 574

no-image

CS1D-DPL02D

Manufacturer Part Number
CS1D-DPL02D
Description
CS1D Dual IO Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-DPL02D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Auxiliary Area Allocations
A526
A527
A528
A529
Word
Addresses
A52600
A52601
A52700
to
A52707
A52709
A52800
to
A52807
A52808
to
A52815
A52900
to
A52915
Bit
RS-232C
Port
Restart
Bit
Periph-
eral Port
Restart
Bit
Online
Editing
Disable
Bit Valida-
tor
Online
Editing
Disable
Bit
RS-232C
Port Error
Flags
Periph-
eral Port
Error
Code
FAL/FALS
Number
for Sys-
tem Error
Simula-
tion
Name
Turn this bit ON to restart the RS-232C
port. (Do not use this bit when the port
is operating in peripheral bus mode.)
This bit is turned OFF automatically
when the restart processing is com-
pleted.
Turn this bit ON to restart the peripheral
port.
This bit is turned OFF automatically
when the restart processing is com-
pleted.
The Online Editing Disable Bit
(A52709) is valid only when this byte
contains 5A.
To disable online editing from a Pro-
gramming Device, set this byte to 5A
and turn ON A52709.
(Online editing refers to changing or
adding to the program while the PLC is
operating in MONITOR mode.)
Turn this bit ON to disable online edit-
ing. The setting of this bit is valid only
when A52700 to A52707 have been set
to 5A.
These flags indicate what kind of error
has occurred at the RS-232C port; they
are automatically turned OFF when the
RS-232C port is restarted.
(These flags are not valid in peripheral
bus mode and only bit 5 is valid in NT
Link mode.)
Bits 0 and 1: Not used.
Bit 2: ON when there was a parity error.
Bit 3: ON when there was a framing
error.
Bit 4: ON when there was an overrun
error.
Bit 5: ON when there was a timeout
error.
Bits 6 and 7: Not used.
These flags indicate what kind of error
has occurred at the peripheral port;
they are automatically turned OFF
when the peripheral port is restarted.
Bits 8 and 9: Not used.
Bit 10: ON when there was a parity
error.
Bit 11: ON when there was a framing
error.
Bit 12: ON when there was an overrun
error.
Bit 13: ON when there was a timeout
error.
Bits 14 and 15: Not used.
Set a dummy FAL/FALS number to use
to simulate the system error using
FAL(006) or FALS(007).
When FAL(006) or FALS(007) is exe-
cuted and the number in A529 is the
same as the one specified in the oper-
and of the instruction, the system error
given in the operand of the instruction
will be generated instead of a user-
defined error.
Function
OFF to ON:
Restart
OFF to ON:
Restart
5A:
A52709
enabled
Other value:
A52709 dis-
abled
ON: Disabled
OFF: Not dis-
abled
See Function
column.
See Function
column.
0001 to 01FF
hex: FAL/FALS
numbers 1 to
511
0000 or 0200
to FFFF hex:
No FAL/FALS
number for sys-
tem error simu-
lation. (No error
will be gener-
ated.)
Settings
Held
Held
Held
Held
Held
Held
Held
change
Status
mode
after
Status at
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
Cleared
startup
---
---
---
---
---
---
---
Timing
Appendix B
---
---
A52709
A52700 to
A52707
---
---
---
Settings
Related
Flags,
539

Related parts for CS1D-DPL02D