CS1D-DPL02D Omron, CS1D-DPL02D Datasheet - Page 413

no-image

CS1D-DPL02D

Manufacturer Part Number
CS1D-DPL02D
Description
CS1D Dual IO Exp
Manufacturer
Omron
Datasheet

Specifications of CS1D-DPL02D

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Instruction Execution Times and Number of Steps
9-5-20 Basic I/O Unit Instructions
378
I/O REFRESH
7-SEGMENT
DECODER
DIGITAL
SWITCH
INPUT
TEN KEY
INPUT
HEXADECI-
MAL KEY
INPUT
MATRIX INPUT MTR
7-SEGMENT
DISPLAY OUT-
PUT
INTELLIGENT
I/O READ
Instruction
IORF
SDEC
DSW
TKY
HKY
7SEG
IORD
IOWR
DLNK
Mnemonic
Note
097
078
210
211
212
213
214
222
223
226
Code
1. When a double-length operand is used, add 1 to the value shown in the
2. Not supported by Duplex CPU Systems.
3. Read/write times depend on the Special I/O Unit for which the instruction
length column in the following table.
is being executed.
3
4
6
4
5
5
5
4
4
4
Length
(steps)
15.5 (sim-
plex)
255.5
(duplex)
17.2 (sim-
plex)
257.2
(duplex)
319.9 (sim-
plex)
559.9
(duplex)
358.0 (sim-
plex)
598.0
(duplex)
6.5
(See note
2.)
(See note
2.)
(See note
2.)
(See note
2.)
(See note
2.)
(See note
3.)
(See note
3.)
287.8 (sim-
plex)
527.8
(duplex)
CPU6@H
(Duplex
CPU)
Execution time ( s)
15.5
17.2
319.9
358.0
6.5
50.7
51.5
51.3
50.7
9.7
10.7
50.3
50.1
47.8
48.0
58.1
63.3
(See note
3.)
(See note
3.)
287.8
CPU6@S
(Single
CPU)
16.4
18.4
320.7
354.4
6.9
73.5
73.4
73.5
73.4
13.2
14.8
70.9
71.2
68.1
68.0
83.3
90.3
(See note
3.)
(See note
3.)
315.5
CPU4@S
(Single
CPU)
1-word refresh for
input words
1-word refresh out-
put words
60-word refresh
input words
60-word refresh
output words
---
4 digits, data input
value: 0
4 digits, data input
value: F
8 digits, data input
value: 0
8 digits, data input
value: F
Data input value: 0
Data input value: F
Data input value: 0
Data input value: F
Data input value: 0
Data input value: F
4 digits
8 digits
---
---
Allocated 1 word
Conditions
Section 9-5

Related parts for CS1D-DPL02D