AM186ES Advanced Micro Devices, AM186ES Datasheet - Page 61

no-image

AM186ES

Manufacturer Part Number
AM186ES
Description
microcontrollers provide a low-cost/ high-performance solution for embedded system designers who wish to use the x86 architecture.
Manufacturer
Advanced Micro Devices
Datasheets

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AM186ES-20KC
Manufacturer:
AMD
Quantity:
1 045
Part Number:
AM186ES-25KC
Manufacturer:
AMD
Quantity:
20 000
Part Number:
AM186ES-25KI/W
Manufacturer:
SICK
Quantity:
1 000
Part Number:
AM186ES-40KC
Manufacturer:
AMD
Quantity:
5 510
Part Number:
AM186ES-40KC
Manufacturer:
XILINX
0
Part Number:
AM186ES-40KC
Manufacturer:
AMD
Quantity:
20 000
Part Number:
AM186ES-40VC
Manufacturer:
AMD
Quantity:
1 831
Part Number:
AM186ES25KCW
Manufacturer:
AMD
Quantity:
5 292
Part Number:
AM186ESLV-20KI
Manufacturer:
AMD
Quantity:
20 000
Part Number:
AM186ESLV-20VC/W
Manufacturer:
AMD
Quantity:
20 000
CHAPTER
4
PERIPHERAL CONTROL BLOCK
4.1
OVERVIEW
The Am186ES and Am188ES microcontroller integrated peripherals are controlled by 16-
bit read/write registers. The peripheral registers are contained within an internal 256-byte
control block—the peripheral control block. Registers are physically located in the
peripheral devices they control, but they are addressed as a single 256-byte block. Table
4-1 shows a map of the peripheral control block registers.
Code that is intended to execute on the Am188ES microcontroller should perform all writes
to the PCB registers as byte writes. These writes will transfer 16 bits of data to the PCB
register even if an 8-bit register is named in the instruction. For example, out dx, al results
in the value of ax being written to the port address in dx. Reads to the PCB should be done
as word reads. Code written in this manner will run correctly on the Am188ES
microcontroller and on the Am186ES microcontroller. Unaligned reads and writes to the
PCB result in unpredictable behavior on both the Am186ES and Am188ES microcontrollers.
The peripheral control block can be mapped into either memory or I/O space. The base
address of the control block must be on an even 256-byte boundary (i.e., the lower eight
bits of the base address are 00h). Internal logic recognizes control block addresses and
responds to bus cycles. During bus cycles to internal registers, the bus controller signals
the operation externally (i.e., the RD, WR, status, address, and data lines are driven as in
a normal bus cycle), but the data bus, SRDY, and ARDY are ignored.
At reset, the Peripheral Control Block Relocation register is set to 20FFh, which maps the
control block to start at FF00h in I/O space. An offset map of the 256-byte peripheral control
register block is shown in Table 4-1. See Section 4.1.1 on page 4-3 for a complete
description of the Peripheral Control Block Relocation register.
Peripheral Control Block
4-1