AM186ES Advanced Micro Devices, AM186ES Datasheet - Page 111
![no-image](/images/manufacturer_photos/0/0/14/advanced_micro_devices_sml.jpg)
AM186ES
Manufacturer Part Number
AM186ES
Description
microcontrollers provide a low-cost/ high-performance solution for embedded system designers who wish to use the x86 architecture.
Manufacturer
Advanced Micro Devices
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
AM186ES-20KC
Manufacturer:
AMD
Quantity:
1 045
Part Number:
AM186ES-25KC
Manufacturer:
AMD
Quantity:
20 000
Company:
Part Number:
AM186ES-25KI/W
Manufacturer:
SICK
Quantity:
1 000
Company:
Part Number:
AM186ES-40KC
Manufacturer:
AMD
Quantity:
5 510
Part Number:
AM186ES-40KC
Manufacturer:
AMD
Quantity:
20 000
Company:
Part Number:
AM186ES-40VC
Manufacturer:
AMD
Quantity:
1 831
Company:
Part Number:
AM186ES25KCW
Manufacturer:
AMD
Quantity:
5 292
Part Number:
AM186ESLV-20KI
Manufacturer:
AMD
Quantity:
20 000
Part Number:
AM186ESLV-20VC/W
Manufacturer:
AMD
Quantity:
20 000
7.3.9
Figure 7-12
Table 7-4
Priority Mask Register
(PRIMSK, Offset 2Ah)
(Master Mode)
The Priority Mask register provides the value that determines the minimum priority level at
which maskable interrupts can generate an interrupt.
Priority Mask Register
The value of PRIMSK at reset is 0007h.
Bits 15–3: Reserved—Set to 0.
Bits 2–0: Priority Field Mask (PRM2–PRM0)—This field determines the minimum priority
that is required for a maskable interrupt source to generate an interrupt. Maskable interrupts
with programmable priority values that are numerically higher than this field are masked.
The possible values are zero (000b) to seven (111b).
A value of seven (111b) allows all interrupt sources that are not masked to generate
interrupts. A value of five (101b) allows only unmasked interrupt sources with a
programmable priority of zero to five (000b to 101b) to generate interrupts.
Priority Level
Priority
(High) 0
(Low) 7
1
2
3
4
5
6
15
0
PR2–PR0
0 0 0
0 0 0b
0 0 1b
0 1 0b
0 1 1b
1 0 0b
1 0 1b
1 1 0b
1 1 1b
Interrupt Control Unit
0
0 0 0
0
7
0 0
PRM2
PRM1
PRM0
0
0
0
7-23