AM186ES Advanced Micro Devices, AM186ES Datasheet - Page 129

no-image

AM186ES

Manufacturer Part Number
AM186ES
Description
microcontrollers provide a low-cost/ high-performance solution for embedded system designers who wish to use the x86 architecture.
Manufacturer
Advanced Micro Devices
Datasheets

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AM186ES-20KC
Manufacturer:
AMD
Quantity:
1 045
Part Number:
AM186ES-25KC
Manufacturer:
AMD
Quantity:
20 000
Part Number:
AM186ES-25KI/W
Manufacturer:
SICK
Quantity:
1 000
Part Number:
AM186ES-40KC
Manufacturer:
AMD
Quantity:
5 510
Part Number:
AM186ES-40KC
Manufacturer:
XILINX
0
Part Number:
AM186ES-40KC
Manufacturer:
AMD
Quantity:
20 000
Part Number:
AM186ES-40VC
Manufacturer:
AMD
Quantity:
1 831
Part Number:
AM186ES25KCW
Manufacturer:
AMD
Quantity:
5 292
Part Number:
AM186ESLV-20KI
Manufacturer:
AMD
Quantity:
20 000
Part Number:
AM186ESLV-20VC/W
Manufacturer:
AMD
Quantity:
20 000
8.3.3
Figure 8-3
Timer 2 Mode and Control Register
(T2CON, Offset 66h)
This register controls the functionality of timer 2. See Figure 8-3.
Timer 2 Mode and Control Register
The value of T2CON at reset is 0000h.
Bit 15: Enable Bit (EN)—When EN is set to 1, the timer is enabled. When set to 0, the
timer is inhibited from counting. This bit cannot be written to unless the INH bit is set to 1
during the same write.
Bit 14: Inhibit Bit (INH)—Allows selective updating of enable (EN) bit. When INH is set to
1 during a write, EN can be modified on the same write. When INH is set to 0 during a write,
writes to EN are ignored. This bit is not stored and is always read as 0.
Bit 13: Interrupt Bit (INT)—When INT is set to 1, an interrupt request is generated when
the count register equals a maximum count. When INT is set to 0, the timer will not issue
interrupt requests. If the EN enable bit is cleared after an interrupt request has been
generated but before the pending interrupt is serviced, the interrupt request remains active.
Bits 12–6: Reserved—Set to 0.
Bit 5: Maximum Count Bit (MC)—The MC bit is set to 1 when the timer reaches its
maximum count. This bit is set regardless of the timer interrupt-enable bit. The MC bit can
be used to monitor timer status through software polling instead of through interrupts.
Bits 4–1: Reserved—Set to 0.
Bit 0: Continuous Mode Bit (CONT)—When CONT is set to 1, it causes the associated
timer to run continuously. When set to 0, EN is cleared after each timer count sequence
and the timer halts on reaching the maximum count.
EN
15
INH
INT
0
0
Timer Control Unit
0 0 0 0 0
7
MC
0
0
0 0
CONT
0
8-5