US38024-BAG1 Renesas Electronics America, US38024-BAG1 Datasheet - Page 196

no-image

US38024-BAG1

Manufacturer Part Number
US38024-BAG1
Description
DEV EVALUATION KIT H8/38024
Manufacturer
Renesas Electronics America
Series
H8®r
Type
MCUr
Datasheet

Specifications of US38024-BAG1

Contents
2G (Second-generation) Evaluation Board, HEW debugger support, Cable and CD-ROM
For Use With/related Products
H8/38024
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Section 6 ROM
6.8.2
When erasing flash memory, the erase/erase-verify flowchart shown in figure 6.11 should be
followed.
1. Prewriting (setting erase block data to all 0s) is not necessary.
2. Erasing is performed in block units. Make only a single-bit specification in the erase block
3. The time during which the E bit is set to 1 is the flash memory erase time.
4. The watchdog timer (WDT) is set to prevent overerasing due to program runaway, etc. An
5. For a dummy write to a verify address, write 1-byte data H'FF to an address whose lower 1 bit
6. If the read data is not erased successfully, set erase mode again, and repeat the erase/erase-
6.8.3
All interrupts, are disabled while flash memory is being programmed or erased, or while the boot
program is executing, for the following three reasons:
1. Interrupt during programming/erasing may cause a violation of the programming or erasing
2. If interrupt exception handling starts before the vector address is written or during
3. If an interrupt occurs during boot program execution, normal boot mode sequence cannot be
Rev. 8.00 Mar. 09, 2010 Page 174 of 658
REJ09B0042-0800
register (EBR). To erase multiple blocks, each block must be erased in turn.
overflow cycle of approximately 19.8 ms is allowed.
is b'0. Verify data can be read in word size from the address to which a dummy write was
performed.
Do not use RTS instruction from dummy write to verify data read. (This does not apply to the
HD64F38124 and HD64F38122.)
verify sequence as before. The maximum number of repetitions of the erase/erase-verify
sequence is 100.
algorithm, with the result that normal operation cannot be assured.
programming/erasing, a correct vector cannot be fetched and the CPU malfunctions.
carried out.
Erase/Erase-Verify
Interrupt Handling when Programming/Erasing Flash Memory

Related parts for US38024-BAG1