AT91SAM7S256D-AU Atmel, AT91SAM7S256D-AU Datasheet - Page 482

no-image

AT91SAM7S256D-AU

Manufacturer Part Number
AT91SAM7S256D-AU
Description
ARM Microcontrollers - MCU 256K Flash SRAM 64K ARM based MCU
Manufacturer
Atmel
Series
SAM7S256r
Datasheet

Specifications of AT91SAM7S256D-AU

Rohs
yes
Core
ARM
Processor Series
AT91SAM
Data Bus Width
16 bit/32 bit
Maximum Clock Frequency
55 MHz
Program Memory Size
256 KB
Data Ram Size
64 KB
On-chip Adc
Yes
Operating Supply Voltage
3 V to 3.6 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
LQFP-64
Mounting Style
SMD/SMT
Interface Type
2-Wire, I2S, SPI, USART
Length
7 mm

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7S256D-AU
Manufacturer:
ATMEL
Quantity:
101
Part Number:
AT91SAM7S256D-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7S256D-AU-999
Manufacturer:
Atmel
Quantity:
10 000
34.3
34.4
34.4.1
34.4.2
34.4.3
34.5
I/O Lines Description
Each channel outputs one waveform on one external I/O line.
Table 34-1.
Product Dependencies
The pins used for interfacing the PWM may be multiplexed with PIO lines. The programmer must first program the
PIO controller to assign the desired PWM pins to their peripheral function. If I/O lines of the PWM are not used by
the application, they can be used for other purposes by the PIO controller.
All of the PWM outputs may or may not be enabled. If an application requires only four channels, then only four
PIO lines will be assigned to PWM outputs.
The PWM is not continuously clocked. The programmer must first enable the PWM clock in the Power Manage-
ment Controller (PMC) before using the PWM. However, if the application does not require PWM operations, the
PWM clock can be stopped when not needed and be restarted later. In this case, the PWM will resume its opera-
tions where it left off.
The PWM interrupt line is connected on one of the internal sources of the Advanced Interrupt Controller. Using the
PWM interrupt requires the AIC to be programmed first. Note that it is not recommended to use the PWM interrupt
line in edge sensitive mode.
Functional Description
The PWM macrocell is primarily composed of a clock generator module and
Name
PWMx
I/O Lines
Power Management
Interrupt Sources
– Clocked by the system clock, MCK, the clock generator module provides 13 clocks.
– Each channel can independently choose one of the clock generator outputs.
– Each channel generates an output waveform with attributes that can be defined independently for each
channel through the user interface registers.
I/O Line Description
Description
PWM Waveform Output for channel x
SAM7S Series [DATASHEET]
4
channels.
Type
Output
6175M–ATARM–26-Oct-12
482

Related parts for AT91SAM7S256D-AU