SAM9X25 Atmel Corporation, SAM9X25 Datasheet - Page 947

no-image

SAM9X25

Manufacturer Part Number
SAM9X25
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM9X25

Flash (kbytes)
0 Kbytes
Pin Count
217
Max. Operating Frequency
400 MHz
Cpu
ARM926
Hardware Qtouch Acquisition
No
Max I/o Pins
105
Ext Interrupts
105
Usb Transceiver
3
Usb Speed
Hi-Speed
Usb Interface
Host, Device
Spi
2
Twi (i2c)
3
Uart
7
Can
2
Lin
4
Ssc
1
Ethernet
2
Sd / Emmc
2
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
12
Adc Resolution (bits)
10
Adc Speed (ksps)
440
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
32
Self Program Memory
NO
External Bus Interface
1
Dram Memory
DDR/LPDDR, SDRAM/LPSDR
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
0.9 to 1.1
Fpu
No
Mpu / Mmu
No/Yes
Timers
6
Output Compare Channels
6
Input Capture Channels
6
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
41.9.9
Name:
Address:
Access:
• REC: Receive Error Counter
When a receiver detects an error, REC will be increased by one, except when the detected error is a BIT ERROR while
sending an ACTIVE ERROR FLAG or an OVERLOAD FLAG.
When a receiver detects a dominant bit as the first bit after sending an ERROR FLAG, REC is increased by 8.
When a receiver detects a BIT ERROR while sending an ACTIVE ERROR FLAG, REC is increased by 8.
Any node tolerates up to 7 consecutive dominant bits after sending an ACTIVE ERROR FLAG, PASSIVE ERROR FLAG or
OVERLOAD FLAG. After detecting the 14th consecutive dominant bit (in case of an ACTIVE ERROR FLAG or an OVER-
LOAD FLAG) or after detecting the 8th consecutive dominant bit following a PASSIVE ERROR FLAG, and after each
sequence of additional eight consecutive dominant bits, each receiver increases its REC by 8.
After successful reception of a message, REC is decreased by 1 if it was between 1 and 127. If REC was 0, it stays 0, and
if it was greater than 127, then it is set to a value between 119 and 127.
• TEC: Transmit Error Counter
When a transmitter sends an ERROR FLAG, TEC is increased by 8 except when
When a transmitter detects a BIT ERROR while sending an ACTIVE ERROR FLAG or an OVERLOAD FLAG, the TEC will
be increased by 8.
Any node tolerates up to 7 consecutive dominant bits after sending an ACTIVE ERROR FLAG, PASSIVE ERROR FLAG or
OVERLOAD FLAG. After detecting the 14th consecutive dominant bit (in case of an ACTIVE ERROR FLAG or an OVER-
LOAD FLAG) or after detecting the 8th consecutive dominant bit following a PASSIVE ERROR FLAG, and after each
sequence of additional eight consecutive dominant bits every transmitter increases its TEC by 8.
After a successful transmission the TEC is decreased by 1 unless it was already 0.
11054A–ATARM–27-Jul-11
11054A–ATARM–27-Jul-11
– the transmitter is error passive and detects an ACKNOWLEDGMENT ERROR because of not detecting a
– the transmitter sends an ERROR FLAG because a STUFF ERROR occurred during arbitration and should
31
23
15
7
dominant ACK and does not detect a dominant bit while sending its PASSIVE ERROR FLAG.
have been recessive and has been sent as recessive but monitored as dominant.
CAN Error Counter Register
30
22
14
CAN_ECR
0xF8000020 (0), 0xF8004020 (1)
Read-only
6
29
21
13
5
28
20
12
4
REC
TEC
27
19
11
3
26
18
10
2
25
17
9
1
SAM9X25
SAM9X25
TEC
24
16
8
0
947