AT32UC3L0256 Atmel Corporation, AT32UC3L0256 Datasheet - Page 539

no-image

AT32UC3L0256

Manufacturer Part Number
AT32UC3L0256
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT32UC3L0256

Flash (kbytes)
256 Kbytes
Pin Count
48
Max. Operating Frequency
50 MHz
Cpu
32-bit AVR
# Of Touch Channels
17
Hardware Qtouch Acquisition
Yes
Max I/o Pins
36
Ext Interrupts
36
Usb Speed
No
Usb Interface
No
Spi
5
Twi (i2c)
2
Uart
4
Lin
4
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
460
Analog Comparators
8
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
Yes
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.62 to 3.6
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
18
Input Capture Channels
12
Pwm Channels
35
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3L0256-AUT
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT32UC3L0256-D3HR
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT32UC3L0256-H
Manufacturer:
ATMEL
Quantity:
270
Part Number:
AT32UC3L0256-H
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
23.6.7
23.6.8
23.6.9
23.6.10
23.6.10.1
32145A–12/2011
Open Drain Mode
Synchronization
Interrupts
Peripheral Events
Input Peripheral Events
Some pins can be used in open drain mode, allowing the PWMA waveform to toggle between
0V and up to 5V on these pins. In this mode the PWMA will drive the pin to zero or leave the out-
put open. An external pullup can be used to pull the pin up to the desired voltage.
To enable open drain mode on a pin the PWMAOD function must be selected instead of the
PWMA function in the I/O Controller. Please refer to the Module Configuration chapter for infor-
mation about which pins are available in open drain mode.
Both the timebase counter and the spread spectrum counter can be reset and the duty cycle
registers can be written through the user interface of the module. This requires a synchroniza-
tion between the PB and GCLK clock domains, which takes a few clock cycles of each clock
domain. The BUSY bit in SR indicates when the synchronization is ongoing. Writing to the mod-
ule while the BUSY bit is set will result in discarding the new value.
Note that the duty cycle registers will not be updated with the new values until the timebase
counter reaches its top value, in order to avoid glitches. The BUSY bit in SR will always be set
during this updating and synchronization period.
When the timebase counter overflows, the Timebase Overflow bit in the Status Register
(SR.TOFL) is set. If the corresponding bit in the Interrupt Mask Register (IMR) is set, an interrupt
request will be generated.
Since the user needs to wait until the user interface is available between each write due to syn-
chronization, a READY bit is provided in SR, which can be used to generate an interrupt
request.
The interrupt request will be generated if the corresponding bit in IMR is set. Bits in IMR are set
by writing a one to the corresponding bit in the Interrupt Enable Register (IER), and cleared by
writing a one to the corresponding bit in the Interrupt Disable Register (IDR). The interrupt
request remains active until the corresponding bit in SR is cleared by writing a one to the corre-
sponding bit in the Status Clear Register (SCR).
The pre-defined channels support input peripheral events from the Peripheral Event System.
Input peripheral events must be enabled by writing a one to the corresponding bit in the Channel
Event Enable Registers (CHEERs) before peripheral events can be used to control the duty
cycle value. Each bit in the register corresponds to one channel, where bit 0 corresponds to
channel 0 and so on. Both the increase and decrease events are enabled for the corresponding
channel when a bit in the CHEER register is set.
An increase or decrease event (event_incr/event_decr) can either increase or decrease the duty
cycle value by one in a PWM period. The events are taken into account when the common time-
base counter reaches its top. The behavior is defined by the Channel Event Response Register
(CHERR). Each bit in the register corresponds to one channel, where bit 0 corresponds to chan-
nel 0 and so on. If the bit in CHERR is set to 0 (default) for a channel, the increase event will
increase the duty cycle value and the decrease event will decrease the duty cycle value for that
channel. If the bit is set to 1, the increase and decrease event will have reverse function so that
AT32UC3L0128/256
539

Related parts for AT32UC3L0256