System-on-Chip Processor

EP9312-CB

Manufacturer Part Number
EP9312-CB
Description
System-on-Chip Processor
Manufacturer
Cirrus Logic Inc
Series
EP9r
Datasheets

Specifications of EP9312-CB

Peak Reflow Compatible (260 C)
No
A/d Converter
12 Bits
Leaded Process Compatible
No
No. Of I/o Pins
65
Package / Case
352-BGA
Core Processor
ARM9
Core Size
16/32-Bit
Speed
200MHz
Connectivity
EBI/EMI, EIDE, Ethernet, I²C, IrDA, Keypad/Touchscreen, SPI, UART/USART, USB
Peripherals
AC'97, DMA, I&sup2:S, LCD, LED, MaverickKey, POR, PWM, WDT
Number Of I /o
16
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 3.6 V
Data Converters
A/D 8x12b
Oscillator Type
External
Operating Temperature
0°C ~ 70°C
Processor Series
EP93xx
Core
ARM920T
Data Bus Width
32 bit
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
No
Other names
598-1257

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP9312-CB
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
EP9312-CB
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
EP9312-CBZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
24
Register Descriptions
PWMxTermCnt
PWMxDutyCycle
24-4
Pulse Width Modulator
EP93xx User’s Guide
15
15
Address:
Default:
Definition:
Bit Descriptions:
Address:
Default:
Definition:
Note: All undefined register bits will be read as 0.
14
14
13
13
12
12
PWM0TermCnt: 0x8091_0000 - Read/Write
PWM1TermCnt: 0x8091_0020 - Read/Write
0x0000_0000
PWMx Terminal Count
PWM_TC:
PWM0DutyCycle: 0x8091_0004 - Read/Write
PWM1DutyCycle: 0x8091_0024 - Read/Write
0x0000_0000
PWMx Duty Cycle
11
11
10
10
Copyright 2007 Cirrus Logic
9
9
PWMxTermCnt is used to adjust the output frequency of
the PWM. PWMxTermCnt gives the PWM up to 16-bit
resolution.
PWMxTermCnt is double buffered to allow it to be
programed statically (PWM is stopped) or dynamically
(PWM is running).
Programmed dynamically, PWMxTermCnt is updated at
the end of a PWM cycle to prevent any output glitches or
errors. Reading the register reflects what was written to it,
not the state of the counter.
8
8
PWM_DC
PWM_TC
7
7
6
6
5
5
4
4
3
3
2
2
1
1
DS785UM1
0
0