UPD70F3769GF-GAT-AX

Manufacturer Part Number
UPD70F3769GF-GAT-AX
Description
MCU 32BIT V850ES/JX3-U 128-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Ur
Datasheet

Specifications of UPD70F3769GF-GAT-AX

Core Processor
RISC
Core Size
32-Bit
Speed
48MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
96
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
56K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3769GF-GAT-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
V850ES/JG3-U, V850ES/JH3-U
17.6.2 SBF transmission/reception format
enable use of the LIN function.
R01UH0043EJ0300 Rev.3.00
Sep 30, 2010
The V850ES/JG3-U and V850ES/JH3-U have an SBF (Sync Break Field) transmission/reception control function to
Remark
Notes 1. The interval between each field is controlled by software.
LIN
bus
TXDCn (output)
INTUCnT
interrupt
Figures 17-8 and 17-9 outline the transmission and reception manipulations of LIN.
2. SBF output is performed by hardware.
3. 80H transfer in the 8-bit mode is substituted for the wakeup signal frame.
4. A transmission enable interrupt request signal (INTUCnT) is output at the start of each transmission.
LIN stands for Local Interconnect Network and is a low-speed (1 to 20 kbps) serial communication protocol
intended to aid the cost reduction of an automotive network.
LIN communication is single-master communication, and up to 15 slaves can be connected to one master.
The LIN slaves are used to control the switches, actuators, and sensors, and these are connected to the LIN
master via the LIN network.
Normally, the LIN master is connected to a network such as CAN (Controller Area Network).
In addition, the LIN bus uses a single-wire method and is connected to the nodes via a transceiver that
complies with ISO9141.
In the LIN protocol, the master transmits a frame with baud rate information and the slave receives it and
corrects the baud rate error. Therefore, communication is possible when the baud rate error in the slave is
±15% or less.
UCnOPT0.UCnSLS2 to UCnOPT0.UCnSLS0 bits.
required,
UCnCTL2.UCnBRS0 bits.
The INTUCnT signal is also output at the start of each SBF transmission.
Wake-up
Note 3
8 bits
signal
frame
such
Note 1
SBF transmission
adjustments
Figure 17-8. LIN Transmission Manipulation Outline
Note 2
13 bits
break
Sync
field
CHAPTER 17 ASYNCHRONOUS SERIAL INTERFACE C (UARTC)
Note 4
can
transmission
be
Sync
55H
field
performed
The output width is the bit length set by the
transmission
Identifier
If even finer output width adjustments are
Data
field
using
transmission
DATA
Data
field
the
UCnCTL2.UCnBRS7
transmission
DATA
Data
field
transmission
Check
Page 742 of 1408
SUM
field
Data
to

Related parts for UPD70F3769GF-GAT-AX