PEB20571FV31XP Infineon Technologies, PEB20571FV31XP Datasheet - Page 79

no-image

PEB20571FV31XP

Manufacturer Part Number
PEB20571FV31XP
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB20571FV31XP

Lead Free Status / Rohs Status
Compliant
LT-T Mode (Unconditional States)
The unconditional states should be left with the command TIM.
• Test mode 1
• Test mode 2
• Reset state
Restriction in LT-T Mode
The two first TRANSIU Channels out of 24, (i.e. Channel_0 and channel_1 in the IOM-
2000 frame, referring to VIP_0, ch_0 and ch_1) do not work in LT-T mode.
In order to have an optimized usage of the LT-channels it is recommended to
proceed as follows:
• If only one VIP is used, 8 channels can be applied in LT-T mode by using a DCL_2000
• If 2 VIPs are used, up to 16 channels can be applied in LT-T mode by using a
• If 3 VIPs are used up to 22 channels (channel 2..23) may be applied in LT-T mode by
Data Sheet
Single alternating pulses are sent on the T interface (2 kHz repetition rate).
Continuous alternating pulses are sent on the T interface (120 kHz).
A hardware or software reset (RES) forces the line interface to an idle state where the
analog components are disabled (transmission of INFO 0) and the T line awake
detector is inactive.
clock of 6.144 MHz and mapping the VIP to channel 8..15.
DCL_2000 of 12.288 MHz and mapping the VIPs to channel 8..23.
using a DCL_2000 of 12.288 MHz.
62
Interface Description
PEB 20570
PEB 20571
2003-07-31

Related parts for PEB20571FV31XP