PEB20571FV31XP Infineon Technologies, PEB20571FV31XP Datasheet - Page 72

no-image

PEB20571FV31XP

Manufacturer Part Number
PEB20571FV31XP
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB20571FV31XP

Lead Free Status / Rohs Status
Compliant
3.2.4.1
Table 24
Command
Deactivate request
Reset
Test mode 1
Test mode 2
Activate request
Deactivate confirmation
(x) unconditional commands
Note: The LT-S state machine does not support loops. So neither C/I commands nor
Indication
Timing
Resynchronizing
Activate request
Code violation received
Activate indication
Deactivate indication
Data Sheet
Indications are provided by the mailbox protocol.
A loop can be programmed by setting bits TICCMR:LOOP and TICCMR:EXLP for
the respective channel.
LT-S Mode
LT-S State Machine Codes
Abbr.
TIM
RSY
AR
CVR
AI
Abbr.
DR
RES
TM1
TM2
AR
DC
DI
Code
0000
0001
0010
0011
1000
1111
Code
0000
0100
1000
1011
1100
1111
55
Remark
Initiates a complete deactivation from the
exchange side by transmitting INFO 0 (x)
(x)
Transmission of pseudo-ternary pulses at
2 kHz frequency (x)
Transmission of pseudo-ternary pulses at
96 kHz frequency (x)
Used to start an exchange initiated
activation
Deactivation acknowledgement, quiescent
state
Remark
INFO 0 received
least one illegal code violation is indicated
four times
Receiver synchronous, i.e., activation
completed
after deactivation request
Receiver is not synchronous
After each multi-frame the reception of at
Timer (32 ms) expired or INFO 0 received
Interface Description
PEB 20570
PEB 20571
2003-07-31

Related parts for PEB20571FV31XP