6
6-4 Setting the Mode
Auxiliary Function Mode
6-21
Key operation
Key operation
Key operation
Alarm Reset
Displaying Auxiliary Function Mode
1. Executing Alarm Reset
2. Returning to Auxiliary Function Mode
Auxiliary Function Mode includes the alarm reset, automatic offset adjustment, absolute encoder
reset, and jog operation.
Display example
Display example
Display example
The item set for the Default Display (Pn01) is displayed.
Press the Data key to display Monitor Mode.
Press the Mode key four times to display Auxiliary Function Mode.
Press the Data key to enter Alarm Reset Mode.
Press and hold the Increment key until “Start” is displayed.
The bar indicator will increase when the key is pressed for 5 s or longer.
The bar indicator will increase.
Alarm reset will start.
This display indicates a normal completion.
“Error” will be displayed if the alarm could not be reset. Reset the power
supply to clear the error.
Press the Data key to return to Auxiliary Function Mode.
Explanation
Explanation
Explanation