MPC564EVB Freescale Semiconductor, MPC564EVB Datasheet - Page 106

KIT EVAL FOR MPC561/562/563/564

MPC564EVB

Manufacturer Part Number
MPC564EVB
Description
KIT EVAL FOR MPC561/562/563/564
Manufacturer
Freescale Semiconductor
Type
Microcontrollerr
Datasheets

Specifications of MPC564EVB

Contents
Module Board, Installation Guide, Power Supply, Cable, Software and more
Processor To Be Evaluated
MPC56x
Data Bus Width
32 bit
Interface Type
RS-232, Ethernet
For Use With/related Products
MPC561, 562, 563, 564
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Signal Descriptions
2-8
BG / VF0 / LWP1
BR / VF1 / IWP2
BB / VF2 / IWP3
IWP[0:1] / VFLS[0:1]
Signal Name
Table 2-1. MPC561/MPC563 Signal Descriptions (continued)
Signals
No. of
1
1
1
2
MPC561/MPC563 Reference Manual, Rev. 1.2
Type
I/O
I/O
I/O
O
O
O
O
O
O
O
O
Controlled by
RCW[DBGC].
See
Controlled by
RCW[DBGC].
See
Controlled by
RCW[DBGC].
See
Controlled by
RCW[DBGC].
See
Function after
Reset
Table
Table
Table 6-8
Table
6-8.
6-8.
6-8.
1
Bus Grant. Indicates external bus status. BG is asserted low
when the external bus arbiter grants ownership of the
external bus to a specific master. This is an active-low signal
and needs an external pull-up resistor to ensure proper
operation and meet signal timing specifications.
Visible Instruction Queue Flush Status 0. This output signal
together with VF1 and VF2 is output by the
MPC561/MPC563 when program instruction flow tracking is
required. VFs report the number of instructions flushed from
the instruction queue in the internal core. See
“Development
Load/Store Watchpoint 1. This output signal reports the
detection of a data watchpoint in the program flow executed
by the RCPU.
Bus Request. Indicates that the external bus has been
requested for external cycle. This is an active-low signal and
needs an external pull-up resistor to ensure proper
operation and meet signal timing specifications.
Visible Instruction Queue Flush Status 1. This output signal
together with VF0 and VF2 is output by the
MPC561/MPC563 when program instruction flow tracking is
required. VFs report the number of instructions flushed from
the instruction queue in the internal core. See
“Development
Instruction Watchpoint 2. This output signal reports the
detection of an instruction watchpoint in the program flow
executed by the RCPU.
Bus Busy. Indicates that the master is using the external
bus. BB is an active-low signal and needs an external
pull-up resistor to ensure proper operation and signal timing
specifications.
Visible Instruction Queue Flush Status 2. This output signal
together with VF0 and VF1 is output by the
MPC561/MPC563 when a program instructions flow
tracking is required. VFs report the number of instructions
flushed from the instruction queue in the internal core.
Instruction Watchpoint 3. This output signal reports the
detection of an instruction watchpoint in the program flow
executed by the internal core.
Instruction Watchpoint [0:1]. These output signals report the
detection of an instruction watchpoint in the program flow
executed by the RCPU.
Visible History Buffer Flush Status [0:1]. These signals are
output by the MPC561/MPC563 to enable program
instruction flow tracking. They report the number of
instructions flushed from the history buffer in the RCPU. See
Chapter 23, “Development
Support,” for more details.
Support,” for more details.
Description
Support,” for details.
Freescale Semiconductor
Chapter 23,
Chapter 23,

Related parts for MPC564EVB