AT91SAM9G45-EKES Atmel, AT91SAM9G45-EKES Datasheet - Page 884

KIT EVAL FOR AT91SAM9G45

AT91SAM9G45-EKES

Manufacturer Part Number
AT91SAM9G45-EKES
Description
KIT EVAL FOR AT91SAM9G45
Manufacturer
Atmel
Series
AT91SAM Smart ARMr
Type
MCUr

Specifications of AT91SAM9G45-EKES

Contents
Board
Processor To Be Evaluated
SAM9G45
Data Bus Width
32 bit
Interface Type
I2C, SPI, UART
Maximum Operating Temperature
+ 50 C
Minimum Operating Temperature
- 10 C
Operating Supply Voltage
1.8 V to 3.3 V
For Use With/related Products
AT91SAM9G45
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4626953
If one toggle sequencing problem occurs among the n-transactions (n = 1, 2 or 3) inside a microframe, then this bit is still
set as long as the current bank contains one “bad” n-transaction. (see
Bank/Control Direction” on page
reset.
Note1: A transaction error occurs when the toggle sequencing does not respect the Universal Serial Bus Specification, Rev
2.0 (5.9.2 High Bandwidth Isochronous endpoints) (Bad PID, missing data....)
Note2: When a transaction error occurs, the user may empty all the “bad” transactions by clearing the Received OUT Data
flag (RX_BK_RDY).
If this bit is reset, then the user should consider that a new n-transaction is coming.
This bit is reset by UDPHS_EPTRST register EPT_x (reset endpoint), and by UDPHS_EPTCTLDISx (disable endpoint).
• RX_SETUP/ERR_FL_ISO: Received SETUP/Error Flow
This bit is set by hardware when a valid SETUP packet has been received from the host.
It is cleared by the device firmware after reading the SETUP data from the endpoint FIFO.
This bit is reset by UDPHS_EPTRST register EPT_x (reset endpoint), and by UDPHS_EPTCTLDISx (disable endpoint).
This bit is set by hardware when a transaction error occurs.
This bit is reset by UDPHS_EPTRST register EPT_x (reset endpoint) and by UDPHS_EPTCTLDISx (disable endpoint).
• STALL_SNT/ERR_CRISO/ERR_NBTRA: Stall Sent/CRC ISO Error/Number of Transaction Error
This bit is set by hardware after a STALL handshake has been sent as requested by the UDPHS_EPTSTAx register
FRCESTALL bit.
This bit is reset by UDPHS_EPTRST register EPT_x (reset endpoint) and by UDPHS_EPTCTLDISx (disable endpoint).
This bit is set by hardware if the last received data is corrupted (CRC error on data).
This bit is updated by hardware when new data is received (Received OUT Data bit).
This bit is set at the end of a microframe in which at least one data bank has been transmitted, if less than the number of
transactions per micro-frame banks (UDPHS_EPTCFGx register NB_TRANS) have been validated for transmission inside
this microframe.
This bit is reset by UDPHS_EPTRST register EPT_x (reset endpoint) and by UDPHS_EPTCTLDISx (disable endpoint).
• NAK_IN/ERR_FLUSH: NAK IN/Bank Flush Error
This bit is set by hardware when a NAK handshake has been sent in response to an IN request from the Host.
This bit is cleared by software.
884
– Received SETUP: (for Control endpoint only)
– Error Flow: (for isochronous endpoint only)
– Isochronous IN transaction is missed, the micro has no time to fill the endpoint (underflow).
– Isochronous OUT data is dropped because the bank is busy (overflow).
– STALL_SNT: (for Control, Bulk and Interrupt endpoints)
– ERR_CRISO: (for Isochronous OUT endpoints) (Read-only)
– ERR_NBTRA: (for High Bandwidth Isochronous IN endpoints)
– NAK_IN:
AT91SAM9G45
885) As soon as the current bank is relative to a new “good” n-transactions, then this bit is
“CURRENT_BANK/CONTROL_DIR: Current
6438F–ATARM–21-Jun-10

Related parts for AT91SAM9G45-EKES