EP3C16F256I7N Altera, EP3C16F256I7N Datasheet - Page 255

no-image

EP3C16F256I7N

Manufacturer Part Number
EP3C16F256I7N
Description
Cyclone III
Manufacturer
Altera
Datasheets

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C16F256I7N
Manufacturer:
IR
Quantity:
14 520
Part Number:
EP3C16F256I7N
Manufacturer:
ALTERA31
Quantity:
214
Part Number:
EP3C16F256I7N
Manufacturer:
ALTERA
Quantity:
90
Part Number:
EP3C16F256I7N
Manufacturer:
XILINX
0
Part Number:
EP3C16F256I7N
Manufacturer:
ALTERA
0
Part Number:
EP3C16F256I7N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP3C16F256I7N
0
Altera Corporation-Preliminary
March 2007
supplied start-up clock option, the CLKUSR pin is the initialization clock
source. Supplying a clock on CLKUSR does not affect the configuration
process. After all configuration data is accepted and CONF_DONE goes
high, Cyclone III devices require 3,180 clock cycles to initialize properly
and enter user mode. Cyclone III devices support a CLKUSR f
MHz.
An optional INIT_DONE pin is available, which signals the end of
initialization and the start of user-mode with a low-to-high transition.
The Enable INIT_DONE Output option is available in the Quartus II
software from the General tab of the Device & Pin Options dialog box.
If the INIT_DONE pin is used, it will be high due to an external 10 KΩ
pull-up resistor when nCONFIG is low and during the beginning of
configuration. Once the option bit to enable INIT_DONE is programmed
into the device (during the first frame of configuration data), the
INIT_DONE pin goes low. When initialization is complete, the
INIT_DONE pin is released and pulled high. This low-to-high transition
signals that the device has entered user mode. When initialization is
complete, the device enters user mode. In user mode, the user I/O pins
no longer have weak pull-up resistors and function as assigned in your
design.
If an error occurs during configuration, Cyclone III devices assert the
nSTATUS signal low, indicating a data frame error, and the CONF_DONE
signal stays low. If the Auto-restart configuration after error option
(available in the Quartus II software from the General tab of the Device
& Pin Options dialog box) is turned on, the Cyclone III device resets the
configuration device by pulsing FLASH_nCE, releases nSTATUS after a
reset time-out period (maximum of 80 µs), and retries configuration. If
this option is turned off, the system must monitor nSTATUS for errors and
then pulse nCONFIG low for at least 500 ns to restart configuration.
When the Cyclone III device is in user mode, you can initiate
reconfiguration by pulling the nCONFIG pin low. The nCONFIG pin
should be low for at least 500 ns. When nCONFIG is pulled low, the
Cyclone III device is reset. The Cyclone III device also pulls nSTATUS and
CONF_DONE low and all I/O pins are tri-stated. When nCONFIG returns
to a logic high level and nSTATUS is released by the Cyclone III device,
reconfiguration begins.
1
If you use the optional CLKUSR pin and the nCONFIG pin is
pulled low to restart configuration during device initialization,
ensure CLKUSR continues to toggle during the time nSTATUS is
low (a maximum of 80 μs).
Active Serial Configuration (Serial Configuration Devices)
Cyclone III Device Handbook, Volume 1
MAX
of 133
10–19