OM13006,598 NXP Semiconductors, OM13006,598 Datasheet - Page 289

BOARD EVAL EM773 METER EU PLUG

OM13006,598

Manufacturer Part Number
OM13006,598
Description
BOARD EVAL EM773 METER EU PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13006,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6681
NXP Semiconductors
UM10415
User manual
20.5.4.2.1 Calculating the RELOAD value
20.5.4.1 SysTick Control and Status Register
20.5.4.2 SysTick Reload Value Register
20.5.4.3 SysTick Current Value Register
The SYST_CSR enables the SysTick features. See the register summary in for its
attributes. The bit assignments are:
Table 256. SYST_CSR bit assignments
The SYST_RVR specifies the start value to load into the SYST_CVR. See the register
summary in
Table 257. SYST_RVR bit assignments
The RELOAD value can be any value in the range 0x00000001-0x00FFFFFF. You can
program a value of 0, but this has no effect because the SysTick exception request and
COUNTFLAG are activated when counting from 1 to 0.
To generate a multi-shot timer with a period of N processor clock cycles, use a RELOAD
value of N-1. For example, if the SysTick interrupt is required every 100 clock pulses, set
RELOAD to 99.
The SYST_CVR contains the current value of the SysTick counter. See the register
summary in
Bits
[31:17]
[16]
[15:3]
[2]
[1]
[0]
Bits
[31:24]
[23:0]
Name
-
COUNTFLAG
-
CLKSOURCE
TICKINT
ENABLE
Table 20–255
Table 20–255
Name
-
RELOAD
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
Function
Reserved.
Value to load into the SYST_CVR when the counter is enabled and
when it reaches 0, see
for its attributes. The bit assignments are:
for its attributes. The bit assignments are:
Function
Reserved.
Returns 1 if timer counted to 0 since the last read of this register.
Reserved.
Selects the SysTick timer clock source:
0 = external reference clock.
1 = processor clock.
Remark: The external reference clock option is not implemented.
This bit reads as 1 and writes to this bit are ignored.
Enables SysTick exception request:
0 = counting down to zero does not assert the SysTick exception
request.
1 = counting down to zero asserts the SysTick exception request.
Enables the counter:
0 = counter disabled.
1 = counter enabled.
Chapter 20: Appendix EM773 ARM Cortex-M0 reference
Section
20.5.4.2.1.
UM10415
© NXP B.V. 2010. All rights reserved.
289 of 310