OM13006,598 NXP Semiconductors, OM13006,598 Datasheet - Page 211

BOARD EVAL EM773 METER EU PLUG

OM13006,598

Manufacturer Part Number
OM13006,598
Description
BOARD EVAL EM773 METER EU PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13006,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6681
NXP Semiconductors
UM10415
User manual
18.4.6 Prepare sector(s) for write operation <start sector number> <end
18.4.7 Copy RAM to flash <Flash address> <RAM address> <no of bytes>
sector number> (UART ISP)
This command makes flash write/erase operation a two step process.
Table 191. UART ISP Prepare sector(s) for write operation command
(UART ISP)
Table 192. UART ISP Copy command
Command
Input
Return Code
Description
Example
Command
Input
Return Code CMD_SUCCESS |
Description
Example
C
Flash Address(DST): Destination flash address where data bytes are to be
written. The destination address should be a 256 byte boundary.
RAM Address(SRC): Source RAM address from where data bytes are to be read.
Number of Bytes: Number of bytes to be written. Should be 256 | 512 | 1024 |
4096.
SRC_ADDR_ERROR (Address not on word boundary) |
DST_ADDR_ERROR (Address not on correct boundary) |
SRC_ADDR_NOT_MAPPED |
DST_ADDR_NOT_MAPPED |
COUNT_ERROR (Byte count is not 256 | 512 | 1024 | 4096) |
SECTOR_NOT_PREPARED_FOR WRITE_OPERATION |
BUSY |
CMD_LOCKED |
PARAM_ERROR |
CODE_READ_PROTECTION_ENABLED
This command is used to program the flash memory. The "Prepare Sector(s) for
Write Operation" command should precede this command. The affected sectors are
automatically protected again once the copy command is successfully executed.
The boot block cannot be written by this command. This command is blocked when
code read protection is enabled.
"C 0 268467504 512<CR><LF>" copies 512 bytes from the RAM address
0x1000 0800 to the flash address 0.
P
Start Sector Number
End Sector Number: Should be greater than or equal to start sector number.
CMD_SUCCESS |
BUSY |
INVALID_SECTOR |
PARAM_ERROR
This command must be executed before executing "Copy RAM to flash" or "Erase
Sector(s)" command. Successful execution of the "Copy RAM to flash" or "Erase
Sector(s)" command causes relevant sectors to be protected again. The boot
block can not be prepared by this command. To prepare a single sector use the
same "Start" and "End" sector numbers.
"P 0 0<CR><LF>" prepares the flash sector 0.
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
Chapter 18: EM773 Flash memory programming firmware
UM10415
© NXP B.V. 2010. All rights reserved.
211 of 310