OM13006,598 NXP Semiconductors, OM13006,598 Datasheet - Page 194

BOARD EVAL EM773 METER EU PLUG

OM13006,598

Manufacturer Part Number
OM13006,598
Description
BOARD EVAL EM773 METER EU PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13006,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6681
NXP Semiconductors
UM10415
User manual
16.6.2.1 Vpp calibration
16.6.2 Calibration procedure
The Metrology Engine can be calibrated by changing the configuration parameters for an
individual meter.
Before calibration, make sure to set the right values for AHBClkFrequency and mains
frequency Fmains with the initialization of the Metrology Engine.
The Calibration Measurements Setup is shown in
The voltage input measurement range Vpp can be calibrated as follows:
Fig 49. EM773 calibration measurements setup
Calculate the initial value for Vpp with the transfer of the analog input circuit in front of
the Metrology Engine and the input range of the VOLTAGE input of the Energy IC
(VSS to VDD). Set the parameter Vpp to this initial value.
Connect an AC reference voltage source to the meter with a reference voltage
(Vsource) and frequency (e.g. 110V/60Hz or 230V/50Hz).
Measure the output value for voltage V. The calibrated value for Vpp can then be
calculated as:
AC Reference Voltage Source
Resistive Load
All information provided in this document is subject to legal disclaimers.
V
Rev. 1 — 10 September 2010
A
Rshunt
R
Vpp
Supply
Power
Opamp
R
=
Vpp
I_HIGHGAIN
I_LOWGAIN
,
initialval
VOLTAGE
V
SS
EM773
ue
Chapter 16: EM773 Metrology engine
Figure
Metrology
engine
V
source
I2C/SPI/UART Power meter
V
49.
V
DD
UM10415
© NXP B.V. 2010. All rights reserved.
Data output
194 of 310
(16)

Related parts for OM13006,598