OM13006,598 NXP Semiconductors, OM13006,598 Datasheet - Page 135

BOARD EVAL EM773 METER EU PLUG

OM13006,598

Manufacturer Part Number
OM13006,598
Description
BOARD EVAL EM773 METER EU PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13006,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6681
NXP Semiconductors
UM10415
User manual
10.12.6.4 State: 0x30
10.12.6.5 State: 0x38
10.12.7.1 State: 0x40
10.12.7.2 State: 0x48
10.12.7.3 State: 0x50
10.12.7 Master Receive states
Data has been transmitted, NOT ACK received. A STOP condition will be transmitted.
Arbitration has been lost during Slave Address + Write or data. The bus has been
released and not addressed Slave mode is entered. A new START condition will be
transmitted when the bus is free again.
Previous state was State 08 or State 10. Slave Address + Read has been transmitted,
ACK has been received. Data will be received and ACK returned.
Slave Address + Read has been transmitted, NOT ACK has been received. A STOP
condition will be transmitted.
Data has been received, ACK has been returned. Data will be read from I2DAT. Additional
data will be received. If this is the last data byte then NOT ACK will be returned, otherwise
ACK will be returned.
6. Write 0x04 to I2CONSET to set the AA bit.
7. Write 0x08 to I2CONCLR to clear the SI flag.
8. Increment Master Transmit buffer pointer
9. Exit
1. Write 0x14 to I2CONSET to set the STO and AA bits.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
1. Write 0x24 to I2CONSET to set the STA and AA bits.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
1. Write 0x04 to I2CONSET to set the AA bit.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
1. Write 0x14 to I2CONSET to set the STO and AA bits.
2. Write 0x08 to I2CONCLR to clear the SI flag.
3. Exit
1. Read data byte from I2DAT into Master Receive buffer.
2. Decrement the Master data counter, skip to step 5 if not the last data byte.
3. Write 0x0C to I2CONCLR to clear the SI flag and the AA bit.
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
Chapter 10: EM773 I2C-bus interface
UM10415
© NXP B.V. 2010. All rights reserved.