OM13006,598 NXP Semiconductors, OM13006,598 Datasheet - Page 208

BOARD EVAL EM773 METER EU PLUG

OM13006,598

Manufacturer Part Number
OM13006,598
Description
BOARD EVAL EM773 METER EU PLUG
Manufacturer
NXP Semiconductors
Type
Other Power Managementr
Datasheets

Specifications of OM13006,598

Design Resources
Plug Meter Schematics, Gerber Files USB Dongle Schematics, Gerber Files
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 32-Bit
Utilized Ic / Part
EM773FHN33,551
Interface Type
USB
Maximum Operating Temperature
+ 150 C
Operating Supply Voltage
1.8 V to 3.6 V
Product
Power Management Development Tools
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Primary Attributes
-
Secondary Attributes
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EM773, OL2381
Other names
568-6681
NXP Semiconductors
18.4 UART ISP commands
UM10415
User manual
18.3.8 RAM used by ISP command handler
18.3.9 RAM used by IAP command handler
ISP commands use on-chip RAM from 0x1000 017C to 0x1000 025B. The user could use
this area, but the contents may be lost upon reset. Flash programming commands use the
top 32 bytes of on-chip RAM. The stack is located at (RAM top − 32). The maximum stack
usage is 256 bytes and it grows downwards.
Flash programming commands use the top 32 bytes of on-chip RAM. The maximum stack
usage in the user allocated stack space is 128 bytes and it grows downwards.
The following commands are accepted by the ISP command handler. Detailed status
codes are supported for each command. The command handler sends the return code
INVALID_COMMAND when an undefined command is received. Commands and return
codes are in ASCII format.
CMD_SUCCESS is sent by ISP command handler only when received ISP command has
been completely executed and the new ISP command can be given by the host.
Exceptions from this rule are "Set Baud Rate", "Write to RAM", "Read Memory", and "Go"
commands.
Table 185. UART ISP command summary
ISP Command
Unlock
Set Baud Rate
Echo
Write to RAM
Read Memory
Prepare sector(s) for
write operation
Copy RAM to flash
Go
Erase sector(s)
Blank check sector(s)
Read Part ID
Read Boot code version K
Compare
ReadUID
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 10 September 2010
Usage
U <Unlock Code>
B <Baud Rate> <stop bit>
A <setting>
W <start address> <number of bytes>
R <address> <number of bytes>
P <start sector number> <end sector number>
C <Flash address> <RAM address> <number of bytes>
G <address> <Mode>
E <start sector number> <end sector number>
I <start sector number> <end sector number>
J
M <address1> <address2> <number of bytes>
N
Chapter 18: EM773 Flash memory programming firmware
UM10415
© NXP B.V. 2010. All rights reserved.
Described in
Table 186
Table 187
Table 188
Table 189
Table 190
Table 191
Table 192
Table 193
Table 194
Table 195
Table 196
Table 198
Table 199
Table 200
208 of 310