DF2148ATE20 Renesas Electronics America, DF2148ATE20 Datasheet - Page 484

IC H8S MCU FLASH 128K 100-QFP

DF2148ATE20

Manufacturer Part Number
DF2148ATE20
Description
IC H8S MCU FLASH 128K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2100r
Datasheets

Specifications of DF2148ATE20

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
Host Interface, I²C, IrDA, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
74
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Other names
HD64F2148ATE20
HD64F2148ATE20

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2148ATE20IV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
DF2148ATE20IV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 15 Serial Communication Interface (SCI, IrDA)
Bit 5—Overrun Error (ORER): Indicates that an overrun error occurred during reception,
causing abnormal termination.
Bit 5
ORER
0
1
Notes: 1. The ORER flag is not affected and retains its previous state when the RE bit in SCR is
Bit 4—Framing Error (FER): Indicates that a framing error occurred during reception in
asynchronous mode, causing abnormal termination.
Bit 4
FER
0
1
Notes: 1. The FER flag is not affected and retains its previous state when the RE bit in SCR is
Rev. 4.00 Sep 27, 2006 page 438 of 1130
REJ09B0327-0400
2. The receive data prior to the overrun error is retained in RDR, and the data received
2. In 2-stop-bit mode, only the first stop bit is checked for a value of 0; the second stop bit
cleared to 0.
subsequently is lost. Also, subsequent serial reception cannot be continued while the
ORER flag is set to 1. In synchronous mode, serial transmission cannot be continued,
either.
cleared to 0.
is not checked. If a framing error occurs, the receive data is transferred to RDR but the
RDRF flag is not set. Also, subsequent serial reception cannot be continued while the
FER flag is set to 1. In synchronous mode, serial transmission cannot be continued,
either.
Description
[Clearing condition]
When 0 is written in ORER after reading ORER = 1
[Setting condition]
When the next serial reception is completed while RDRF = 1 *
Description
[Clearing condition]
When 0 is written in FER after reading FER = 1
[Setting condition]
When the SCI checks the stop bit at the end of the receive data when reception ends,
and the stop bit is 0 *
2
2
(Initial value) *
(Initial value) *
1
1