LM3S600-IQN20-A0T Bookham Technology, Inc., LM3S600-IQN20-A0T Datasheet - Page 33

no-image

LM3S600-IQN20-A0T

Manufacturer Part Number
LM3S600-IQN20-A0T
Description
Microcontroller
Manufacturer
Bookham Technology, Inc.
Datasheet
October 01, 2007
SysTick Current Value Register
Use the SysTick Current Value Register to find the current value in the register.
SysTick Calibration Value Register
The SysTick Calibration Value register is not implemented.
Bit/Field
Bit/Field
31:24
23:0
23:0
RELOAD
CURRENT
reserved
Name
Name
Type
W1C
Type
W1C
RO
Reset
Reset
-
0
-
Description
Value to load into the SysTick Current Value Register when the counter reaches 0.
Description
Software should not rely on the value of a reserved bit. To provide compatibility with
future products, the value of a reserved bit should be preserved across a
read-modify-write operation.
Current value at the time the register is accessed. No read-modify-write protection is
provided, so change with care.
This register is write-clear. Writing to it with any value clears the register to 0. Clearing
this register also clears the COUNTFLAG bit of the SysTick Control and Status Register.
Preliminary
LM3S600 Microcontroller
33

Related parts for LM3S600-IQN20-A0T