Specifications of PEF2256EV22NP

Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Supplier Unconfirmed
Receive CAS Register (Read)
Value after reset: not defined
Table 68
RS1
RS2
RS3
RS4
RS5
RS6
RS7
RS8
RS9
RS10
RS11
RS12
RS13
RS14
RS15
RS16
Receive CAS Register (16:1)
Each register except RS1 contains the received CAS bits for two time slots. The received
CAS multiframe is compared to the previously received one. If the contents changed a
CAS multiframe changed interrupt (ISR0.CASC) is generated and informs the user that
a new multiframe has to be read within the next 2 ms. If requests for reading the
RS(16:1) register are ignored, the received data is lost. RS1 contains frame 0 of the CAS
multiframe. MSB is received first.
Additionally a receive signaling data change pointer indicates an update of register
RS(16:1). Refer also to register RSP(2:1).
Access to RS(16:1) registers is only valid if the serial receive signaling access on the
system highway is disabled.
Data Sheet
Receive CAS Registers (E1)
A10
A11
A12
A13
A14
A15
A1
A2
A3
A4
A5
A6
A7
A8
A9
7
0
B10
B11
B12
B13
B14
B15
B1
B2
B3
B4
B5
B6
B7
B8
B9
0
C10
C11
C12
C13
C14
C15
C1
C2
C3
C4
C5
C6
C7
C8
C9
0
D10
D11
D12
D13
D14
D15
D1
D2
D3
D4
D5
D6
D7
D8
D9
0
344
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
X
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
Y
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
X
Rev. 1.1, 2005-06-13
D16
D17
D18
D19
D20
D21
D22
D23
D24
D25
D26
D27
D28
D29
D30
X
0
PEF 2256 H/E
E1 Registers
FALC
(7A)
(7B)
(7C)
(7D)
(7E)
(7F)
(70)
(71)
(72)
(73)
(74)
(75)
(76)
(77)
(78)
(79)
®
56

Related parts for PEF2256EV22NP