PEF2256EV22NP Lantiq, PEF2256EV22NP Datasheet - Page 296

PEF2256EV22NP

Manufacturer Part Number
PEF2256EV22NP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF2256EV22NP

Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Supplier Unconfirmed
RFT13, RFT03
Common Configuration Register 5 (Read/Write)
Value after reset: 00
CCR5
CSF2
SUET
CSF
Data Sheet
7
RFIFO3 Threshold Level - HDLC Channel 3
The size of the accessible part of RFIFO3 can be determined by
programming these bits. The number of valid bytes after an RPF
interrupt is given in the following table:
RFT13
0
0
1
1
The value of RFT13/03 can be changed dynamically if reception is not
running or after the current data block has been read, but before the
command CMDR4.RMC3 is issued (interrupt controlled data
transfer).
Note:These bits are only valid, if SS7 mode of HDLC channel 1 is
Compare Status Field - Mode 2
0 =
1 =
Signaling Unit Error Threshold
Defines the number of signaling units received in error that will cause
an error rate high indication (ISR1.SUEX).
0 =
1 =
Compare Status Field
If the status fields of consecutive LSSUs are equal, only the first is
stored and every following is ignored.
CSF2
H
selected.
Compare disabled, if consecutive FISUs are equal, only the first
is stored and all following are ignored.
Compare enabled, if consecutive FISUs are equal, the first two
are stored and all following are ignored (according to ITU-T
Q.703).
Threshold 64 errored signaling units
Threshold 32 errored signaling units
SUET
RFT03
0
1
0
1
CSF
Size of Accessible Part of RFIFO3
32 bytes (default value)
16 bytes
4 bytes
2 bytes
296
AFX
Rev. 1.1, 2005-06-13
PEF 2256 H/E
E1 Registers
0
FALC
(x8D)
®
56

Related parts for PEF2256EV22NP