PEF2256EV22NP Lantiq, PEF2256EV22NP Datasheet - Page 101

PEF2256EV22NP

Manufacturer Part Number
PEF2256EV22NP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF2256EV22NP

Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Supplier Unconfirmed
6.3
6.3.1
Alarm Indication Signal: Detection and recovery is flagged by bit FRS0.AIS and
ISR2.AIS. Transmission is enabled by bit FMR1.XAIS.
Loss-Of-Signal: Detection and recovery is flagged by bit FRS0.LOS and ISR2.LOS.
Remote Alarm Indication: Detection and release is flagged by bit FRS0.RRA, RSW.RRA
and ISR2.RA/RAR. Transmission is enabled by bit XSW.XRA.
AIS in time slot 16: Detection and release is flagged by bit FRS1.TS16AIS and
ISR3.AIS16. Transmission is enabled by writing all ones in registers XS(16:1).
LOS in time slot 16: Detection and release is flagged by bit FRS1.TS16LOS.
Transmission is enabled by writing all zeros in registers XS(16:1).
Remote Alarm in time slot 16: Detection and release is flagged by bit FRS1.TS16RA and
ISR3.RA16. Transmission is enabled by bit XS1.2.
Transmit Line Shorted: Detection and release is flagged by bit FRS1.XLS and
ISR1.XLSC.
Transmit Ones-Density: Detection and release is flagged by bit FRS1.XLO and
ISR1.XLSC.
Table 23
Alarm
Loss-Of-Signal
(LOS)
Alarm Indication
Signal (AIS)
Remote Alarm
(RRA)
Data Sheet
Additional Receive Framer Functions (E1)
Error Performance Monitoring and Alarm Handling
Summary of Alarm Detection and Release (E1)
Detection Condition
No transitions (logical
zeros) in a programmable
time interval of 16 to 4096
consecutive pulse periods.
Programmable receive
input signal threshold
FMR0.ALM = 0:
less than 3 zeros in
250 µs and loss of frame
alignment declared
FMR0.ALM = 1:
less than 3 zeros in
each of two consecutive
250-µs periods
Bit 3 = 1 in time slot 0 not
containing the FAS word
101
Clear Condition
Programmable number of ones (1
to 256) in a programmable time
interval of 16 to 4096 consecutive
pulse periods. A one is a signal
with a level above the
programmed threshold.
FMR0.ALM = 0:
more than 2 zeros in
250 µs
FMR0.ALM = 1:
more than 2 zeros in each of two
500-µs periods
Set conditions no longer
detected.
Functional Description E1
Rev. 1.1, 2005-06-13
PEF 2256 H/E
FALC
®
56

Related parts for PEF2256EV22NP