PEF2256EV22NP Lantiq, PEF2256EV22NP Datasheet - Page 312

PEF2256EV22NP

Manufacturer Part Number
PEF2256EV22NP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF2256EV22NP

Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Supplier Unconfirmed
Framer Receive Status Register 0 (Read)
FRS0
LOS
AIS
Data Sheet
LOS
7
Loss-of-Signal
Detection:
This bit is set when the incoming signal has “no transitions” (analog
interface) or logical zeros (digital interface) in a time interval of T
consecutive pulses, where T is programmable by register PCD.
Total account of consecutive pulses: 16 < T < 4096.
Analog interface: The receive signal level where “no transition” is
declared is defined by the programmed value of LIM1.RIL(2:0).
Recovery:
Analog interface: The bit is reset in short-haul mode when the
incoming signal has transitions with signal levels greater than the
programmed receive input level (LIM1.RIL(2:0)) for at least M pulse
periods defined by register PCR in the PCD time interval. In long-haul
mode additionally bit RES.6 must be set for at least 250µsec.
Digital interface: The bit is reset when the incoming data stream
contains at least M ones defined by register PCR in the PCD time
interval.
With the rising edge of this bit an interrupt status bit (ISR2.LOS) is set.
The bit is also set during alarm simulation and reset, if FMR0.SIM is
cleared and no alarm condition exists.
Alarm Indication Signal
The function of this bit is determined by FMR0.ALM.
FMR0.ALM = 0: This bit is set when two or less zeros in the received
bit stream are detected in a time interval of 250 s and the FALC
is in asynchronous state (FRS0.LFA = 1). The bit is reset when no
alarm condition is detected (according to ETSI standard).
FMR0.ALM = 1: This bit is set when the incoming signal has two or
less Zeros in each of two consecutive double frame period (512 bits).
This bit is cleared when each of two consecutive doubleframe periods
contain three or more zeros or when the frame alignment signal FAS
has been found. (ITU-T G.775)
The bit is also set during alarm simulation and reset if FMR0.SIM is
cleared and no alarm condition exists.
With the rising edge of this bit an interrupt status bit (ISR2.AIS) is set.
AIS
LFA
RRA
312
NMF
LMFA
Rev. 1.1, 2005-06-13
PEF 2256 H/E
E1 Registers
0
FALC
(4C)
®
®
56
56