PEF2256EV22NP Lantiq, PEF2256EV22NP Datasheet - Page 154

PEF2256EV22NP

Manufacturer Part Number
PEF2256EV22NP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF2256EV22NP

Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Supplier Unconfirmed
Figure 54
different external actions. Activation of auto mode and non-auto mode is performed by
bit FMR4.AUTO. Generally, for initiating resynchronization it is recommended to use bit:
FMR0.EXLS first. In cases where the synchronizer remains in the asynchronous state,
bit FMR0.FRS is used to enforce it to lock onto the next framing candidate, although it
might be a simulated one.
7.2.4
The allocation of the FT-bits (bit 1 of frames 1 and 3) for frame alignment signal is shown
in
The FS-bit can be used for signaling. Remote alarm (yellow alarm) is indicated by setting
bit 2 to 0 in each time slot.
Table 36
Frame Number
1
2
3
4
7.2.4.1
For multiframe synchronization, the terminal framing bits (FT-bits) are observed. The
synchronous state is reached if at least one terminal framing candidate is definitely
found, or the synchronizer is forced to lock onto the next available candidate
(FMR0.FRS).
Data Sheet
Table
36.
gives an overview of influences on synchronization status for the case of
4-Frame Multiframe (F4 Format, T1/J1)
Synchronization Procedure
4-Frame Multiframe Structure (T1/J1)
F
1
0
T
154
Functional Description T1/J1
F
service bit
service bit
S
Rev. 1.1, 2005-06-13
PEF 2256 H/E
FALC
®
56

Related parts for PEF2256EV22NP