PEF2256EV22NP Lantiq, PEF2256EV22NP Datasheet - Page 321

PEF2256EV22NP

Manufacturer Part Number
PEF2256EV22NP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF2256EV22NP

Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Supplier Unconfirmed
CRC Error Counter 1 (Read)
CEC1L
CEC1H
CR(15:0)
Data Sheet
CR15
CR7
7
7
CRC Errors
No function if doubleframe format is selected.
In CRC-multiframe mode, the 16-bit counter is incremented when a
CRC-submultiframe has been received with a CRC error. CRC errors
are not counted during asynchronous state. The error counter does
not roll over.
During alarm simulation, the counter is incremented once per
submultiframe up to its saturation.
Clearing and updating the counter is done according to bit
FMR1.ECM.
If this bit is reset the error counter is permanently updated in the
buffer. For correct read access of the error counter bit DEC.DCEC1
has to be set. With the rising edge of this bit updating the buffer is
stopped and the error counter is reset. Bit DEC.DCEC1 is reset
automatically with reading the error counter high byte.
If FMR1.ECM is set every second (interrupt ISR3.SEC) the error
counter is latched and then automatically reset. The latched error
counter state should be read within the next second.
321
Rev. 1.1, 2005-06-13
PEF 2256 H/E
CR0
CR8
E1 Registers
0
0
FALC
(54)
(55)
®
56