SAM3U2C Atmel Corporation, SAM3U2C Datasheet - Page 850

no-image

SAM3U2C

Manufacturer Part Number
SAM3U2C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U2C

Flash (kbytes)
128 Kbytes
Pin Count
100
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
28
Hardware Qtouch Acquisition
No
Max I/o Pins
57
Ext Interrupts
57
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
4
Twi (i2c)
1
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
36
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
37.14.8
Name:
Address:
Access:
This register can only be written if the WPEN bit is cleared in
• CSTOCYC: Completion Signal Timeout Cycle Number
These fields determine the maximum number of Master Clock cycles that the HSMCI waits between two data block trans-
fers. Its value is calculated by (CSTOCYC x Multiplier).
• CSTOMUL: Completion Signal Timeout Multiplier
These fields determine the maximum number of Master Clock cycles that the HSMCI waits between two data block trans-
fers. Its value is calculated by (CSTOCYC x Multiplier).
These fields determine the maximum number of Master Clock cycles that the HSMCI waits between the end of the data
transfer and the assertion of the completion signal. The data transfer comprises data phase and the optional busy phase. If
a non-DATA ATA command is issued, the HSMCI starts waiting immediately after the end of the response until the comple-
tion signal.
Multiplier is defined by CSTOMUL as shown in the following table:
If the data time-out set by CSTOCYC and CSTOMUL has been exceeded, the Completion Signal Time-out Error flag
(CSTOE) in the HSMCI Status Register (HSMCI_SR) rises.
850
850
31
23
15
7
Value
SAM3U Series
SAM3U Series
HSMCI Completion Signal Timeout Register
0
1
2
3
4
5
6
7
30
22
14
HSMCI_CSTOR
0x4000001C
Read-write
6
1048576
Name
65536
1024
4096
CSTOMUL
128
256
16
1
29
21
13
5
Description
CSTOCYC x 1
CSTOCYC x 16
CSTOCYC x 128
CSTOCYC x 256
CSTOCYC x 1024
CSTOCYC x 4096
CSTOCYC x 65536
CSTOCYC x 1048576
28
20
12
4
“HSMCI Write Protect Mode Register” on page
27
19
11
3
26
18
10
2
CSTOCYC
25
17
9
1
6430E–ATARM–29-Aug-11
6430E–ATARM–29-Aug-11
866.
24
16
8
0

Related parts for SAM3U2C