SAM3U2C Atmel Corporation, SAM3U2C Datasheet - Page 1004

no-image

SAM3U2C

Manufacturer Part Number
SAM3U2C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U2C

Flash (kbytes)
128 Kbytes
Pin Count
100
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
28
Hardware Qtouch Acquisition
No
Max I/o Pins
57
Ext Interrupts
57
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
4
Twi (i2c)
1
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
36
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
• RX_SETUP/ERR_FL_ISO: Received SETUP/Error Flow Interrupt Enabled
0 = Received SETUP/Error Flow Interrupt is masked.
1 = Received SETUP/Error Flow Interrupt is enabled.
• STALL_SNT/ERR_CRISO/ERR_NBTRA: Stall Sent/ISO CRC Error/Number of Transaction Error Interrupt Enabled
0 = Stall Sent/ISO CRC error/number of Transaction Error Interrupt is masked.
1 = Stall Sent /ISO CRC error/number of Transaction Error Interrupt is enabled.
• NAK_IN/ERR_FLUSH: NAKIN/Bank Flush Error Interrupt Enabled
0 = NAKIN Interrupt is masked.
1 = NAKIN/Bank Flush Error Interrupt is enabled.
• NAK_OUT: NAKOUT Interrupt Enabled
0 = NAKOUT Interrupt is masked.
1 = NAKOUT Interrupt is enabled.
• BUSY_BANK: Busy Bank Interrupt Enabled
0 = BUSY_BANK Interrupt is masked.
1 = BUSY_BANK Interrupt is enabled.
• SHRT_PCKT: Short Packet Interrupt Enabled
1004
1004
For OUT endpoints: an interrupt is sent when all banks are busy.
For IN endpoints: an interrupt is sent when all banks are free.
For OUT endpoints: send an Interrupt when a Short Packet has been received.
0 = Short Packet Interrupt is masked.
1 = Short Packet Interrupt is enabled.
For IN endpoints: a Short Packet transmission is guaranteed upon end of the DMA Transfer, thus signaling a BULK or
INTERRUPT end of transfer or an end of isochronous (micro-)frame data, but only if the UDPHS_DMACONTROLx
register END_B_EN and UDPHS_EPTCTLx register AUTO_VALID bits are also set.
SAM3U Series
SAM3U Series
6430E–ATARM–29-Aug-11
6430E–ATARM–29-Aug-11